OptiX RTN 600
Product Description
Commercial in Confidence
Page 16 of 44
Chapter 4 RF Configuration
4.1 1+0 Configuration
For a 1+0 microwave transmission system, there is one active channel and there is no
standby channel.
4.1.1 Configuration Requirements
Table 4-1
Requirements for 1+0 configuration
Component
Configuration Requirement
IF1A/IF1B
1 PCS
ODU
1 PCS
Antenna
1 PCS
4.1.2 System Block Diagram
Service
interface
unit
IF unit
ODU
RF signal
IF signal
IDU
Cross-connect unit
Service
signal
Fan and
power
unit
Clock
unit
Control
unit
Auxiliary
interface
unit
Antenna
Control and
overhead bus
Figure 4-1
Block diagram of a 1+0 microwave transmission system