Installing the OAU 2F
Installation procedure
8
Use the Web LCT to configure NE data.
Align antennas.
Check the installation.
Connected to a
power supply
device
Power on the OAU 2F.
Commissioning procedure
1
2
3
4
6
10GE1(o)
7
1
2
3
5
Connected to one 10GE
(optical) service
Grounded through
the ground clip
4
Install an outdoor fiber or network cable.
Connect an outdoor fiber or network cable to a port.
Lay out the outdoor fiber or network cable.
Attach a yellow label to the fiber or network cable, and write a number on the label
according to the plan.
5
Install a DC power cable.
Connect a DC power cable to the DC power port in the maintenance compartment.
Lay out the DC power cable.
Select ground points for the DC power cable, and install ground clips.
Attach a matte white label to the DC power cable.
6
Install an IF cable. Connect the IF ports of the OAU 2F and XMC ODU using an IF cable.
7
Waterproof DC power cable, ground clips, and IF cable connectors.
3
Install the XMC ODU on the OAU 2F.
Install the joining kit on the XMC ODU.
Install the XMC ODU on the OAU 2F.
Install the joining modules of the XMC ODU
and OAU 2F on the antenna.
When the XMC-3/3H ODU is used, first
install the joining modules of the XMC
ODU and OAU 2F on the hybrid coupler
together with the other XMC ODU, and
then install the coupler on the antenna.
When the XMC-5D ODU is used, install
only the joining modules of the XMC ODU
and OAU 2F on the antenna.
2
3
Install the XMC ODU on the antenna.
2
Install the OAU 2F on a pole or wall.
Integrated installation
Split installation
4
IF2
IF1
7
DC
power
cable
DC
power
cable
Connect to a
ground bar
2
Installation at a 2+0 or 1+1 Site
In the example integrated installation, the
XMC-3/3H ODU is used.
For the method of making and laying out an IF cable, see the RTN XMC ODU Quick Installation
Guide.
Do not remove or insert an IF cable connector from or to the OAU 2F with power on. Otherwise,
human injuries may be caused.
For details about how to install the XMC
ODU, see
RTN XMC ODU Quick
Installation Guide.
The GE1(e) or GE2(e) port can be used
to transmit/receive electrical services, and
the 10GE1(o) or 10GE2(o) port can be
used to transmit/receive optical services.
In this example, the 10GE1(o) port is
used.
For the method of installing an antenna,
follow the antenna installation guide
delivered with the antenna.
1
Install a ground cables of the OAU 2F and
XMC ODU .
Install the device-side ground cable before
you climb up the tower.
1
Install a ground cable of the OAU 2F.
Install the device-side ground cable
before you climb up the tower.