OptiX OSN 7500
Technical Manual - System Description
10 Technical Specifications
Huawei Technologies Proprietary
10-17
Item
Sub-item
Range
Note:
Impact response spectrum: The curve of the maximum acceleration response generated by
the equipment under the stipulated impact motivation. Impact response spectrum II indicates
the duration of semi sinusoidal impact spectrum is 6ms.
Static load: The pressure from upside, that the equipment with package can endure when
the equipment is piled as stipulated.
10.8.3 Environment for Operation
1.
Climate
Table 10-26 and Table 10-27 show the required climate environment in which the
OptiX OSN 7500 operates.
Table 10-26
Requirements for temperature and humidity
Temperature
Relative humidity
Long-term
operation
Short-term
operation
Long-term
operation
Short-term
operation
0
°
C–45
°
C –5
°
C to 55
°
C
10%–90% 5%–95%
Note:
Temperature and humidity values are obtained 1.5 m above the floor and 0.4 m in front of the
equipment.
Short-term operation means the consecutive working time of the equipment does not
exceed 96 hours, and the accumulated working time every year does not exceed 15 days
Table 10-27
Other climate requirements
Item
Range
Altitude
≤
4000 m
Air pressure
70 kPa–106 kPa
Temperature change rate
≤
5
°
C/h
Solar radiation
≤
700 W/s²
Heat radiation
≤
600 W/s²
Air speed
≤
1 m/s