OptiX OSN 8800/6800/3800
Hardware Description
4 OptiX OSN 8800 Subrack
Issue 01 (2016-03-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
31
Unit Name Typical Power
Consumption
(W)
a
Maximum
Power
Consumption
(W)
a
Remarks
(enhanced
subrack)
SLO16, 4 x SLQ16, 4 x SLH41, 4 x
EGSH, 2 x STG, 1 x STI, 2 x SCC,
8 x PIU, 2 x AUX, 1 x EFI1, 1 x
EFI2, 1 x ATE, and 4 x fan tray
assembly
a: Indicates that the power consumption of the subrack and cabinet is the value in a certain
configuration. The value is for reference only. The actual power consumed by the chassis
and cabinet is a calculation based on the power consumption of each module. The
maximum power consumption is the power consumed by the board when it works normally
under the highest ambient temperature.
4.2.7 Mechanical Specifications
lists the mechanical specifications of the OptiX OSN 8800 T64 subrack.
Table 4-20
Mechanical specifications of the OptiX OSN 8800 T64
Item
Specification
Dimensions
498 mm (W) × 580 mm (D) × 900 mm (H)
(19.6 in. (W) × 22.8 in. (D) × 35.4 in. (H))
Weight (empty subrack
a
)
65 kg (143 lb.)
a: An empty subrack means no boards are installed in the board area, and no fan tray
assembly or air filter is installed.
4.3 OptiX OSN 8800 T32 Subrack
There are two types of OptiX OSN 8800 T32 subracks: enhanced and general.
In this document, "OptiX OSN 8800 T32" refers to both enhanced OptiX OSN 8800 T32 and
general OptiX OSN 8800 T32 subracks unless otherwise specified.
Enhanced subracks and general subracks are two types of subracks. Although they have the same
appearance, the backplane bandwidth, electrical cross-connect capabilities, corresponding cross-connect
boards, and supported service boards are different. Pay special attention to the differences when using
and replacing the subracks.
4.3.1 Structure
Subracks are the basic working units of the OptiX OSN 8800 T32. Each subrack has
independent power supplies.