Figure 9-1
Turn off the
power supply and check whether the C1823/C1822 is
short circuited.
Replace the
U1801.
No
Check whether
the output voltage of the U9000/U9001/U9002/U9003
is normal.
Check whether
the U9000/
U9001/U9002/
U9003 is short
circuited.
No
Yes
Check whether the
output voltage of the U1001/U1000/U1002 is normal.
Yes
No
Check whether
the U1001/
U1000/U1002 is
short circuited.
Yes
Replace the U4.
Startup failure due to high