14
figure1-18
R_UIM card interface module signals
Signal
Source or target module
Function
VREG_PHONE
Inter-board interface
module
UIM card power supply
RUIM_RST
Inter-board interface
module
UIM card resetting signal
RUIM _CLK
Inter-board interface
module
UIM card clock signal
RUIM _DAT
Inter-board interface
module
UIM bi-directional data signal
RUIM _EN
Inter-board interface
module
UIM enabling signal
VDD_ SIM of ETS2000 series FWT is powered by the power management chip on
the TCPC board. R-UIM_EN directly provides power for the UIM card. See Figure
1-14.
Figure1-14
ETS2000 series FWT VDD_SIM power supply
1.3.2 Power Supply and Power Management Sub-System
1. DC/DC power Module
The external power over voltage protection module protects the input power. When
the input voltage exceeds 30V, the protection circuit will function. Then the silicon
controlled thyristor is in the continuity status and the self-healing fuse F301 will be
blown. Thus, the power protection circuit will be cut (The function is only to be
fulfilled on the Indian BSNL FWT). The circuit is shown in Figure 1-16.