eSpace IAD104H
Quick Start
4
Manual Configuration (CLI)
Issue 10 (2019-04-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
20
Make calls to verify the correctness of the configuration.
If calls can be made or received successfully, it indicates
that the data is configured correctly.
If a fault exists, check whether the data is correctly configured.
If the data is correct but the fault persists, see the eSpace IAD
Troubleshooting Guide to locate the fault.
4.3 Accessing NGN/IP PBX (MGCP)
The users of the IAD104H register with the softswitch (for
example, Softx3000 and U1900) to implement the voice
service. After configuring the softswitch data, configure the
IAD104H data to use the voice service, including basic call
and fax services.
Data Plan
In this example, the Softx3000 functions as the MGC server.
You can obtain the connection data between the IAD and the
Softx3000 from the network carrier or network administrator.
The following data is for reference only.
Table 4-3
Connection data between the IAD and the Softx3000
Item
Parameter Value
Parameter and Value on
the IAD
Control protocol
used between the
SoftX3000 and
the IAD
MGCP protocol
Protocol mode: MGCP
IP address of the
IFMI board on
the SoftX3000
192.168.1.70/255.25
5.255.0
IP address of the MGC
server: 192.168.1.70