Fireproof precautions: 

l

 Keep the device away from large heat source equipment, bare flames, and high-power devices, 

such as electric heaters, candles, and blow drier, to eliminate safety risks. 

l

 If there are aged cables or power socket facilities on the power supply line to or near the device, 

replace them in time to eliminate safety risks. The power supply voltage of the device must meet 

the input voltage requirement. 

 

Laser Safety 

Detailed description: 

l

 Keep the optical ports of the module clean, and cap them when they are not used. 

l

 Prevent the end faces of the optical interfaces of the module from being damaged by hard 

objects. 

l

 Exercise caution when removing and reinserting the fibers for the SC optical ports on the module. 

Do not damage the ceramic sockets of optical components. 

l

 The goldfinger unit of the module supports no more than 50 times of removal and reinsertion. 

l

 Laser products that are safe during use, including long-term direct intrabeam viewing, even when 

exposure occurs while using optical viewing instruments (eye loupes or binoculars). Class 1 also 

includes high power lasers that are fully enclosed so that no potentially hazardous radiation is 

accessible during use (embedded laser product).Intrabeam viewing of Class 1 laser products 

which emit visible radiant energy may still produce dazzling visual effects, particularly in low 

ambient light. 

l

 Do not look into fiber end faces without eye protection using an optical meter (such as magnifier 

and microscope) within 100 mm, unless you ensure that the laser output is disabled. When 

operating an optical meter, observe the operation requirements. 

l

 This device complies with IEC 60825-1: 2007-03 Rules. 

Output average power:

 

l

 Under normal circumstances, the maximum optical output average power of the optical module 

is 8.0dBm. In the abnormal case, output average power of the optical module is less than 11 

dBm. 

Nameplate information: 

l

 Class 1 warning sign is written on the product lable, which is posted on the product. 

l

 “Complies with 21 CFR 1040.10 and 1040.11 except for deviations Pursuant to Laser Notice 

No.50,dated June 24,2007” is written on the product lable, which is posted on the product. 

l

 The manufacturer’s address and production date information is reflected in the product lable, 

which is attached on the above of the product. 

Feature   

Agency 

Standard 

Laser Eye Safety

 

FDA/CDRH 

CDRH 21 CFR 1040 and Laser Notice 50

 

Laser Eye Safety

 

TÜV 

IEC 60825-1:2007,Edition 2 
IEC 60825-1:2014,Edition 3 
IEC 60825-2:2004+A1:2006+A2:2010

 

Electrical Safety

 

TÜV 

EN 60950 

 

 

 

Summary of Contents for Echolife HG8245Q5

Page 1: ...ur hands before connecting or disconnecting cables Stop the device and switch off the power before connecting or disconnecting cables l Do not place any object on the device so that the device will not be damaged due to overheating or deformation l Prevent objects such as metal from entering the device through the heat dissipation hole l Switch off the power and disconnect all cables including the...

Page 2: ...n is accessible during use embedded laser product Intrabeam viewing of Class 1 laser products which emit visible radiant energy may still produce dazzling visual effects particularly in low ambient light l Do not look into fiber end faces without eye protection using an optical meter such as magnifier and microscope within 100 mm unless you ensure that the laser output is disabled When operating a...

Page 3: ... HG8245 series About 320 g 18 W HG8247 series About 400 g 24 W If the appearance of the product in this document differs from the actual product the actual product prevails Installing the GPON Terminal 1 Do not install PON terminals outdoors or on the outdoor cabinets 2 PON terminals can be mounted onto a wall or be placed on a workbench Do not install PON terminals in other modes such as the ceil...

Page 4: ...unting a GPON terminal onto the wall Only supported by some product models Step 1 Mark the positions of two holes used for mounting a GPON terminal ensure that the two holes have the same spacing as the two mounting holes Step 2 Select a proper drill according to the outer diameter of the screws Use a hammer drill to drill the marked positions on the wall Then clean the wall and install two expans...

Page 5: ...tually supported by the device If the external device is different from the device in the figure see the description for connections of the external device This document lists connections of typical devices NOTE NOTE Wi Fi terminal 1 2 5 6 4 PC IP STB Power socket Fax machine Phone TV set Optical port TV set 3 USB storage device 8 9 7 1 The optical fiber connector connected to the optical port on ...

Page 6: ...r name and password printed on the nameplate of the device and click Login After the password is authenticated the web configuration window is displayed 10 Optical port NOTE NOTE l Shipped from different manufacture batches the nameplates of some devices do not have the IP address user name and password printed In such a case log in to the device using 192 168 100 1 root user name and adminHW pass...

Page 7: ...e meter To better receive signals devices should be installed at places where signals can directly traverse walls or ceilings 3 Note the impact of building materials on the wireless network coverage A metal door or aluminum wall may limit the coverage of a wireless network Install access points wireless routers and computers so signals can traverse walls or open passageways Materials and objects s...

Page 8: ...n The USB port is connected and is working in the host mode but no data is transmitted Blinks twice a second Data is being transmitted on the USB port Off The system is not powered on or the USB port is not connected TEL1 TEL2 Steady on The terminal is registered with the softswitch but no service flows are transmitted Blinking Service flows are transmitted Off The terminal is not powered on or fa...

Page 9: ...uant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not oc...

Page 10: ...not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FAQs The LOS indicator blinks l If the LOS indicator blinks once two seconds check whether the pigtail fiber is properly connected and the connector is clean l If the GPON terminal blinks twice a second contact the service provider for help The PON indicator is off l Check whethe...

Page 11: ...td 2018 All rights reserved No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co Ltd Issue 02 2018 06 07 BOM number 3150xxxx PASS Qualification Card ...

Page 12: ...arefully fill in the required information and preserve this card in good condition User Information Personal or Company s full name Address Postal Code T elephone Email Product Type Product Serial Number Purchase Date Invoice Number Dealer s Name Dealer s Address Dealer s T elephone Preserve well No reissue Dealer s Seal ...

Page 13: ... caused by the fact that the product is dismantled or altered by anyone that is not from a Huawei authorized service partner 3 The defects are caused by the fact that the product is used in a harsh environment that is not suitable for the operation of the product 4 The defects are caused by any force majeure including but not limited to fire earthquake lightning and tsunami 5 The defects are cause...

Reviews: