Cable
One End
The Other End
Connector
Installation
Position
Connector
Installation
Position
DLC
connector
l
CPRI port on
the GTMU
or UBRI in
the BBU
l
CPRI port on
the WBBP in
the BBU
l
CPRI port on
the LBBP in
the BBU
DLC connector
CPRI_W or
CPRI0 port on
the RRU
Signal Cables
and
list the signal cables that have been installed before delivery.
lists the signal cables to be installed onsite.
Table 7-8
Signal cables installed before delivery (in an AC cabinet)
Cable
One End
The Other End
Connector
Installation
Position
Connector
Installation
Position
7.8.7 Monitoring
Signal Cable for
the Door Status
Sensor
Bare wire
Door status
sensor
Bare wire
GATE port on
the HEUB
Monitoring signal
cable for the inner
air circulation fan
4-pin
connector
IntFAN port on
the HEUB
4-pin connector
Power and
monitoring port
for the inner air
circulation fan
Monitoring signal
cable for the outer
air circulation fan
4-pin
connector
ExtFAN port on
the HEUB
4-pin connector
Power and
monitoring port
for the outer air
circulation fan
7.8.3 PMU 11A
Monitoring
Signal Cable
RJ45
connector
COM_OUT port
on the HEUB
RJ45 connector
COM_IN port
on the PMU11A
in the
ETP48100-A1
RJ45
connector
RJ45 port on the
ELU
RJ45 connector
ELU port on the
HEUB
BTS3900C (Ver.C)
Hardware Description
7 BTS3900C Cables
Issue 03 (2013-05-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
126