HUAWEI BTS3012 Fast Installation Guide Internal Use
18
Installing
signal cables
Signal cables at the top of the cabinet include:
Digital signal input cable
Digital signal output cable
Monitoring signal cable
Anti-lightning failure alarm cable
Environment monitoring device signal cable
The following table shows the connection relationship between signal cables and interface boards at
the top of the cabinet:
Type of signal
cable
Interface at the top of
the cabinet
Type of
connector at the
top of the cabinet
Peer equipment
Digital signal
input cable
SWIN interface of the
DMLC
MD68 male
connector
Related controlling
equipment
Digital signal
output cable
SWOUT interface of the
DMLC
DB15 male
connector
Related controlling
equipment
Monitoring signal
cable
AIN interface of the DMLC DB44 male
connector
DDF
Anti-lightning failure
alarm cable
S1+S1- interfaces of the
DSAC
2PIN phoenix
terminal
Lightning arrester of
power
Anti-lightning failure
alarm cable of
combined cabinets
S1+S1-, and S2+S2-
interfaces of the DSAC
2PIN phoenix
terminal
Corresponding
interface of the slave
cabinet
Environment
monitoring device
signal cable
COM1 port and COM2 port
of the DSAC
DB9 male
connector
Environment
monitoring device
The installation specifications of signal cables at the top of the cabinet are the same as the
installation specifications of E1 cables. For details, refer to the E1 cable installation specifications.
Install electrical adjusted signal cables
Installation
Refer to the
HUAWEI BTS3012 Base Station Installation Manual-Cabinet Installation
.
Install signal cables of combined cabinets
Installation
Refer to the
HUAWEI BTS3012 Base Station Installation Manual-Cabinet Installation
.
Install combined signal cables
Installation
Refer to the
HUAWEI BTS3012 Base Station Installation Manual-Cabinet Installation
.
Install equipotential cables of combined cabinets
Installation
Refer to the
HUAWEI BTS3012 Base Station Installation Manual-Cabinet Installation
.
Install optical fibers