Installing Cables
9
Connecting the ground
bar
●
Connecting the ground cable
Cut the cable of proper length, and select 6-M4 OT terminal for the AP and 6-M6 OT terminal for the ground bar.
Requirements for laying out ground cables:
1. All ground cables must be connected to a ground bar.
2. The ground cable cannot be led in aerially, but buried in the earth or arranged indoor.
3. Both ends of the external conductor of the coaxial cable and those of the insulation of the shielded cable should
have good electric contact with the metal shell of the equipment they connect to.
4. Ground cables must be separated from signal cables to reduce interference between them.
5. Do not add any switch or fuse on the ground cable.
6. Do not use another device for an electrical connection with the ground cable.
7. All metal components in the shell must be securely connected to the ground cable.
Keep the screw properly and install it again after pressing the Reset button.
CAUTION
●
Pressing the Reset Button
The Reset button on an outdoor AP is protected by a waterproof screw. Before pressing the Reset button, remove the
waterproof screw.
CAUTION