Context
shows the components of an RJ45 connector and a shielded Ethernet cable.
Figure 5-15
Shielded RJ45 connector and cable
A. Jacket of connector
B. Metal shell of connector
C. Wire holder of
connector
D. Plug of connector
E. Jacket of Ethernet cable F. Shield layer of Ethernet
cable
G. Twisted-pair wires
-
Procedure
Step 1
Fit the jacket of the connector onto the Ethernet cable, as shown in
Figure 5-16
Fitting the jacket of the connector onto the Ethernet cable
Step 2
Remove a 30 mm (1.18 in.) long section of the jacket, cut off the nylon twine inside the
jacket, and cut a no more than 5 mm (0.20 in.) cleft in the jacket, as shown in
.
R250D
Hardware Installation and Maintenance Guide
5 Appendix
Issue 01 (2016-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
32