![Huawei 3010 Troubleshooting Manual Download Page 87](http://html.mh-extra.com/html/huawei/3010/3010_troubleshooting-manual_169671087.webp)
Model
Minimum
Configuration
Remarks
RH5885H V3
Two CPUs in the CPU1
and CPU2 sockets
One PSU in any slot
One DIMM in the DIMM
A1 slot of the first
memory board
1288H V5, 1288X V5, 2288
V5, 2288C V5, 2288H V5,
2288X V5, 5288 V5, 5288X
V5
One CPU in the CPU1
socket
One PSU in any slot
One DIMM in the
DIMM000(A) slot
2298 V5
Two CPUs in the CPU1
and CPU2 sockets
One PSU in any slot
One DIMM in the
DIMM000(A) slot
2488 V5, 2488H V5, 5885H
V5
Two CPUs in the CPU1
and CPU2 sockets
None
One DIMM in the
DIMM000(A) slot
XH321 V5, XH321L V5
One CPU in the CPU1
socket
None
One DIMM in the
DIMM000(A) slot
XH628 V5
One CPU in the CPU1
socket
The RAID controller
card is mounted to
CPU 2. If the OS drive
is connected to the
RAID controller card,
the OS cannot be
accessed.
One DIMM in the
DIMM000(A) slot
CH121 V5, CH242 V5,
CH121L V5, and CH221 V5
One CPU in the CPU1
socket
None
One DIMM in the
DIMM000 slot
CH225 V5
Two CPUs in the CPU1
and CPU2 sockets
None
One DIMM in the
DIMM000(1A1) slot
Atlas 800 AI training server
(model 9010)
Two CPUs in the CPU1
and CPU2 sockets
None
Huawei Servers
Troubleshooting
5 Diagnosing and Rectifying Faults
Issue 20 (2020-09-25)
Copyright © Huawei Technologies Co., Ltd.
78