Indicator
Status
Meaning
Diagnosis
Procedure
Off
The port is not
connected.
Indicators Available Only on the Atlas 800 AI Training Server (Model 9010)
Table 5-17 Fan module indicators
Indicator
Status
Meaning
Diagnosis
Procedure
Fan module
indicator
Off
The fan module
has no power
supply.
Check whether
the fan module is
installed properly
and whether its
control circuit is
functioning
correctly.
Steady green
The fan module is
operating
properly.
N/A
Blinking red
The fan module
has reported an
alarm.
1. Log in to the
iBMC WebUI
and check fan
alarms.
2. Check whether
the power
connector of
the fan module
is properly
connected, or
replace the fan
module.
Table 5-18 Network port indicators
Indicator
Status
Meaning
Diagnosis Procedure
2 x 100GE optical
port connection
status indicators
Steady
green
The network port is
connected properly.
N/A
Blinking
green
Data is being
transmitted.
Huawei Servers
Troubleshooting
5 Diagnosing and Rectifying Faults