Huaao NBC series Operation Manual Download Page 12

(3)

 

Rotary Knob of Electrical Inductance 

This rotary knob is used to change the welding stability, depth of molten pool, and quantity of 

splashing droplets. 

1.5.3Storage/Display Area 

 

1.5.3.1Digital Tube of Passage Number Display 

The digital tube displays the passage numbers ranging from 0 to 9. Users can store or invoke the 

ten suites of diameter specifications based on actual demand. 

(1)

 

Passage selection: When you press the passage button repeatedly, the number changes in the 

sequence of 0 to 9. Select one passage number. 

(2)

 

Storage: When you press the storage button once, the passage number blinks for three seconds, 

during which if you press the button again, the current state of the control panel and welding 

specifications are stored into this passage. 

(3)

 

Invoke: After you press the invoke button, the passage recording the current state of control 

panel  and  welding  specifications  is  invoked.  At  the  invoke  state,  the  PROG  indicator  is  on, 

and adjustment to the panel state or welding specifications is not allowed. When you press the 

invoke button again, the passage quits the invoked state. 

(4)

 

Diameter  specifications:  When  you  turn  simultaneously  the  arc  stopping  voltage  knob  and 

electrical  inductance  knob  and  last  for  one  second,  the  diameter  specifications  of  currently 

used  welding  wire  is  invoked,  which  is  favorable  for  sampling  and  maintenance.  When  you 

press the invoke button, the current state is quited. 

1.5.3.2Digital Tube of Current Display 

The digital tube displays the wire feed rate, the current, and period of spot welding. 

(1)

 

The M/min indicator is on when the digital tube displays the preset wire feed rate. 

(2)

 

The  A  indicator  is  on  when  the  digital  tube  displays  the  current.  At  the  no-load  state,  the 

digital tube displays the preset current, and at the welding state, it displays the actual current. 

(3)

 

The S indicator is on when the digital tube displays the preset period of spot welding. 

(4)

 

When  you  turn  simultaneously  the  arc  stopping  current knob  and  arc  stopping  voltage  knob 

and last for one second, the digital tube displays the preset current and preset wire feed rate in 

turn. 

1.5.3.3Digital Tube of Voltage Display 

The digital tube displays the electrical inductance and voltage. 

(1)

 

The  digital  tube  displays  the  value  of  electrical  inductance,  and  the  –  indicator  is  on,  when 

you adjust the electrical inductance value, ranging from 1 to 50. 

(2)

 

The  digital  tube  displays  the  voltage  value,  and  the  V  indicator  is  on,  when  you  adjust  the 

Storage 

Passage 

Invoke 

welding 

Arc stopping 

Summary of Contents for NBC series

Page 1: ...chines Save this manual and keep it handy for quick reference Pay particular attention to the safety instructions we have provided for your protection Contact your distributor if you do not fully unde...

Page 2: ...arts please contact the local dealers maintain stations with the Warranty Retention of users or a copy of invoice as a certificate so as to get specified maintain service If the user can not provide t...

Page 3: ...will be caused The symbol above is applicable to the general occasion The serious injury mentioned above refers to eyesight damage trauma harm electric shock fracture and poisoning and so on which wil...

Page 4: ...Work to the following items in case of electric shock Once contact the position with electricity the fatal electric shock or heat injury will be caused 1 Never contact electrified position 2 Invite el...

Page 5: ...ing area 4 When weld the steel plate with electroplate or coating the harmful dust and gas will produce please use protection appliance for breath Arc light will cause the inflammation of eye or heat...

Page 6: ...en the gas bottle is unused 8 Never put welding torch on the gas bottle electrode can not contact gas bottle 1 Never use welding machine on the condition of dismounting machine shell 2 Invite the prof...

Page 7: ...gging work 2 To prevent insulation deterioration caused by powder accumulation please be sure to maintain and examine and repair regularly 3 If splashing iron powder etc go in the power please be sure...

Page 8: ...contents 1 NBC DIGITAL series welding machine application and feature 2 equipment install and connection 3 operation and manual 4 others 5 Appendix A Feedback Table...

Page 9: ...h preceding NBC II series welding machine it has the following new functions and features Better appearance of weld lower possibility of deformation Higher success rate of arc starting due to the appl...

Page 10: ...welding cable from a wire feeder 1 3 indicates a negative terminal which connects the output cable that connects the workpiece 1 4 indicates a control socket connecting the RD 1 digital controller opt...

Page 11: ...ng 1 two steps working mode Turn on the switch on the welding torch to start welding and turn off it to stop welding This working mode is applicable to short seam welding 2 Four steps working mode Pre...

Page 12: ...he arc stopping voltage knob and electrical inductance knob and last for one second the diameter specifications of currently used welding wire is invoked which is favorable for sampling and maintenanc...

Page 13: ...f time regulating for lead gas transmission In this case the digital tube displays 811 and indicator S is on Turn the arc stopping voltage knob to adjust the time of lead gas transmission which ranges...

Page 14: ...g of preset current and preset wire feed rate 1 When you press simultaneously the arc stopping current button and arc stopping voltage button and hold them for one second the digital tube displays the...

Page 15: ...NBC 500III NBC 630III Input power 3 Phase AC380V 3 Phase AC380V 3 Phase AC380V Cable Input side 2 5 mm2 6 mm2 10 mm2 Output side 35 mm2 70 mm2 95 mm2 Ground cable 2 5 mm2 6 mm2 10 mm2 4 Ground Bolt T...

Page 16: ...the knob slightly to left or right 4 RD I Digital Controller The controller is optional To use this controller plug the control plug into the control socket as shown in figure 1 1 4 For details on th...

Page 17: ...Wiring diagram Main control board Driver board Front panel Wire feeder...

Page 18: ...Jinan Huaao electric welding machine Co Ltd No 182 41 Gongye North Rd Lieheng Jinan Shandong 250100 China Tel 0531 8863 8666 Fax 0531 8866 5381 E mail yu xia jnhuaao cn http www jnhuaao cn...

Reviews: