CONTROL  PADS  ON  THE  DEHUMIDIFIER

Control pads

3

When you push the button to change

operation modes, the unit will make 

a beep sound to indicate that it is 

changing modes.

NOTE: The control panel of the unit you purchased may be slightly different according to the 

models. 

Fig.1

2

Humidity Set Control Pads

: Down/Up Pads

TIMER Set Control Pads

Use the Up/Down pads to set the Auto start and 

Auto stop time from 0.0 to 24.

The humidity level can be set within a range of 

35%RH(Relative Humidity) to 85%RH(Relative 

Humidity) in 5% increments.

For drier air, press the      pad and set to a lower 

percent value(%). 

For damper air, press the      pad and set  a higher 

percent value(%).

CONTROL  PADS  ON  THE  DEHUMIDIFIER

Other features 

Bucket Full Light

Glows when the bucket  is ready to be 

emptied, or when the bucket is removed

or not replaced in the proper position.

When frost builds up on the evaporator coils, the 

compressor will cycle off and the fan will continue 

to run until the frost disappears.

NOTE:When Auto defrosting operation,the unit may 

make a voice of refrigerant flowing,it is normal.

Auto Defrost

Wait 3 minutes before resuming operation

After the unit has stopped,  it can not be restart 

opertation in the first 3 minutes. This is to protect 

the unit. Operation will automatically start after 

3 minutes.

Setting the Timer

 When the unit is on, first  press the Timer 

 button,  the Timer Off indicator light 

 illuminates. It indicates the Auto Stop 

 program is initiated. Press it again the 

 Time On indecator light illuminates.It 

 indicates the Auto Start is initiated.

 When the unit is off, first  press the Timer 

 button, the TIMER ON indicator light 

 illuminates. It indicates the Auto Start 

 program is initiated. Press it again the 

 Time Off indecator light illuminates.It 

 indicates the Auto Stop is initiated.

 Press or hold the UP or DOWN pad to 

 change the Auto time by 0.5 hour incre-

 ments,  up to 10 hours, then at 1 hour 

 increments up to 24 hours. The control  

 will count down the time remaining until 

 start. 

 The selected time will register in 5 seconds 

 and the system will automatically revert 

 back to display the previous humidity 

 setting.

 When the Auto start & Auto stop times are

 set, within the same program sequence, 

 TIMER ON OFF indicator lights illuminate 

  identifying both ON and OFF times are

  now programmed.

 Turning the unit ON or OFF at any time or 

 adjusting the timer setting to 0.0 will cancel

 the Auto Start/Stop function.

 When LED display window displays the

 code of  P2, the Auto Start/Stop function 

 will also be cancelled.

Display

Shows the set % humidity level from 35% to 85% or auto 

start/stop time (0~24) while setting, then shows the actual

(

±

5% accuracy) room % humidity level in a range of 

RH(Relative Humidity) to 90%RH(Relative Humidity).

Error Codes and Protection Codes:

AS

- Humidity sensor error--Unplug the unit and plug it back

in. If error repeats, call for service.

ES

- Temperature sensor error-- Unplug the unit and plug it 

back in. If error repeats, call for service.

30%

5

Timer Pad

Press to initiate the Auto start and Auto stop feature, 

in conjuction with the       and         key pads.

Auto Shut Off

The 

 shuts off when the bucket  is full, 

or when the bucket is removed or not replaced in 

the proper position.When the setting humidity is 

reached, the unit will be shut off automatically. 

For some models,the fan motor will continue 

operating.

dehumidifier

Auto-Restart

If the unit breaks off unexpectedly due to the power cut, 

it will restart with the previous function setting automa-

tically when the power resumes.

1

4

Power Pad

Press to turn the dehumidifier on and off.

1

2

3

4

5

6

7

Unit operation on

indicator light

8

High fan 

indicator light

Timer on/off

indicator light

Ion operation on

indicator light

Bucket full 

indicator light

Continuous

operation on

indicator light

Dryer operation 

on indicator light

Smart dehumidifying

operation on indicator 

light

Mode Pad

Press to select the desired operation mode from

Dehumidifying,Dryer,Continuous dehumidifying and

Smart dehumidifying. 

NOTE: Dryer and Smart dehumidifying modes are

optional.

 

6

Turbo Pad

7

Ion Pad(optional)

Press to activate the ionizer. Anions ar automatically

generated by ionization. The anions deactive the

airborne chemical vapors and dust particles. Press

it again to stop the function.

Control the fan speed. Press to select either High 

or Normal fan speed. Set the fan control to High for  

maximum moisture removal. When the humidity has 

been reduced and quiet operation is preferred, set 

the fan control to Normal.

8

P1

- Unit is defrosting-- Allow the unit time to automatically

defrost. The protection will clear after the unit self defrosts.

P2

- Bucket is full or bucket is not in right position-- Empty 

the bucket and replace it in the right position.

E3

- Unit malfunction-- Unplug the unit and plug it back in. If 

error repeats, call for service.

Smart dehumidifying mode(optional)

At smart dehumidifying mode, the unit will automatically 

control room humidity in a comfortable range 45%~55% 

according to the room temperature. The humidity setting 

function will be invalid.

EC

- Refrigerant leakage detection-- With this new technology,

the display area will appear   EC   when the unit detects 

refrigerant leakage ,call for service.

Summary of Contents for HTWDB30X2

Page 1: ...OWNER S MANUAL DEHUMIDIFIER X2 HTWDB30X2 Thanks for choose our product Please read carefully this manual before use the product ENGLISH...

Page 2: ...ast free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least...

Page 3: ...k of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play the appliance...

Page 4: ...d Do not place the unit near a heat source Before cleaning turn off the power and unplug the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc CAUTION...

Page 5: ...nit If water enters the unit turn the unit off and disconnect the power contact a qualified service technician Do not place flower vases or other water container on top of the unit The manufactures na...

Page 6: ...Power Pad Press to turn the dehumidifier on and off 1 2 3 4 5 6 7 Unit operation on indicator light 8 High fan indicator light Timer on off indicator light Ion operation on indicator light Bucket ful...

Page 7: ...imes are now programmed Turning the unit ON or OFF at any time or adjusting the timer setting to 0 0 will cancel the Auto Start Stop function When LED display window displays the code of P2 the Auto S...

Page 8: ...s automatically controlled according to the actual room humidity The unit will quit dryer mode after a maximum 10 hours operation NOTE The Dryer mode must be operated in a close room do not open the d...

Page 9: ...spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of...

Page 10: ...in its correct position NOTES When you remove the bucket do not touch any parts inside of the unit Doing so may damage the product Be sure to push the bucket gently all the way into the unit Banging...

Page 11: ...an the bucket Every few weeks clean the bucket to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and add a little mild detergent Swish it around in the bucket em...

Page 12: ...umidity control may not be set low enough Check that all doors windows and other openings are securely closed O O Room temperature is too low below 5 C 41 F There is a kerosene heater or something giv...

Page 13: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info htwspain com www htwspain com...

Page 14: ......

Reviews: