background image

12

14

13

FOLLOW ME Button

(

applicable to RG57A3/BGEF

  

Push this button to initiate the Follow Me 
feature, the remote display is actual 
temperature at its location. The remote 
control will send this signal to the air 
conditioner every 3 minutes interval until 
press the Follow Me button again. The air 
conditioner will cancel the Follow Me feature 
automatically if it does not  receive the signal 
during any 7 minutes interval. 

MODE

FAN

TEMP

SLEEP  FRESH

LED  FOLLOW ME

TURBO SELF CLEAN

ON/OFF

SHORT

   CUT

TIMER

  ON

TIMER

  OFF

1

2

4
5

3

9

10

8

6

7

11

12

13

14

     Swing      Button

(

applicable to RG57A3/BGEF

 

     Swing     Button

(

applicable to RG57A3/BGEF

 

Used to stop or start horizontal louver move-
ment or set the desired up/down air flow
direction. The louver changes 6 degree in 
angle for each press. If keep pushing more 
than 2 seconds, the louver will swing  up and 
down automatically.

Used to stop or start vertical louver movement 
and set the desired left/right air flow direction.
The vertical louver changes 6 degree in angle
for each press. And the temperature display 
area of indoor unit displays         for one 
second. If keep pushing more than 2 seconds, 
the vertical louver swing feature is activated. 
And the display area of indoor unit displays
   

   , flashes four times, then the tempera-

IIII

ture setting reverts back. If the vertical louver 
swing feature is stopped, it displays  LC   and 
remains on for 3 seconds.

,

,

,

,

,

,

LED Button

Disable/Active indoor screen Display. When 
pushing the button, the indoor screen display 
is cleared, press it again to light the display.
 

     SWING Button

(

applicable to RG57B/BGE

  

     DIRECT Button

(

applicable to RG57B/BGE

  

Used to change the louver movement and set
the desired up/down air flow direction. 

O

The louver changes 6  in angle for each press. 

 

Used to stop or start horizontal louver auto 
swing feature.

MODE

FAN

TEMP

ON/OFF

SHORT

   CUT

TIMER

  ON

TIMER

  OFF

1

2

4

3

9

10

8

6

11

12

SLEEP  

TURBO

SWING   DIRECT

LED

14

RG57B/BGE

RG57A3/BGEF

OPERATION OF BUTTONS

30

Summary of Contents for HTW-RG57

Page 1: ...HTW RG57 ENGLISH OWNER S MANUAL REMOTE CONTROL Thanks for choossing our product Please read carefully this manual before using the product...

Page 2: ...F RG57A3 BGEF RG57A2 BGEF FRESH function is not available Remote Controller Specifications Environment Signal Receiving Range 5C 60C MODE MODE FAN FAN TEMP TEMP SLEEP FRESH SLEEP TURBO SWING DIRECT LE...

Page 3: ...tain the most comfortable temperature and save energy This function is available on COOL HEAT or AUTO mode only Active Disable When the FRESH function is initiated the Ionizer Plasma Dust Collector de...

Page 4: ...ments to 17 C DOWN Button 8 10 11 9 Press this button to initiate the auto on time sequence Each press will increase the auto timed setting in 30 minutes increments When the setting time displays 10 0...

Page 5: ...op or start vertical louver movement and set the desired left right air flow direction The vertical louver changes 6 degree in angle for each press And the temperature display area of indoor unit disp...

Page 6: ...dium speed High speed Auto fan speed Note of clear presentation But during the actual operation only the relative functional signs are shown on the display window All indicators shown in the figure ar...

Page 7: ...e The OPERATION indicator on the display panel of the indoor unit starts flashing 1 Press the MODE button to select Auto 2 Press the UP DOWN button to set the desired temperature The temperature can O...

Page 8: ...w direction 1 Up Down direction can be adjusted with the button on the remote controller Each time when you press the button the louver moves an angle of 6 degree If pressing more than 2 seconds the l...

Page 9: ...ignal H will disappear and the set temperature will re appear on the LCD display window To set the Auto on time To set the Auto off time 1 Press the TIMER OFF button The remote controller shows TIMER...

Page 10: ...ton the last setting of starting operation time and the signal H will show on the display area 2 Press the TIMER ON button to display 6 0H on the TIMER ON display of the remote controller 3 Wait for 3...

Page 11: ...wake up or when you return home Example COMBINED TIMER S both ON and OFF etting timers simultaneously Start 10 hours later after setting Example TIMER ON TIMER OFF Off Start Stop operation This featur...

Page 12: ...cation of the remote controller Using the remote controller holder optional CAUTIONS The air conditioner will not operate if curtains doors or other materials block the signals from the remote control...

Page 13: ...e new batteries placing the and ends correctly 3 Install the cover back on NOTE When the batteries are removed the remote controller erases all programming After inserting new batteries the remote con...

Page 14: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 93 390 42 20 Fax 93 390 42 05 info htwspain com www htwspain com...

Reviews: