9. Checks to electrical devices
10. Repairs to sealed components
the charge size is in accordance with the room size within which the refrigerant containing
parts are installed;
the ventilation machinery and outlets are operating adequately and are not obstructed;
if an indirect refrigerating circuit is being used, the secondary circuits shall be checked
for the presence of refrigerant; marking to the equipment continues to be visible and
legible.
marking and signs that are illegible shall be corrected;
refrigeration pipe or components are installed in a position where they are unlikely to be
exposed to any substance which may corrode refrigerant containing components, unless
the components are constructed of materials which are inherently resistant to being
corroded or are suitably protected against being so corroded.
Repair and maintenance to electrical components shall include initial safety checks and
component inspection procedures. If a fault exists that could compromise safety, then no
electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault
cannot be corrected immediately but it is necessary to continue operation, and adequate
temporary solution shall be used. This shall be reported to the owner of the equipment so all
parties are advised.
Initial safety checks shall include:
that capacitors are discharged: this shall be done in a safe manner to avoid possibility of
sparking
that there no live electrical components and wiring are exposed while charging, recovering
or purging the system;
that there is continuity of earth bonding.
10.1 During repairs to sealed components, all electrical supplies shall be disconnected from the
equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely
necessary to have an electrical supply to equipment during servicing, then a permanently
operating form of leak detection shall be located at the most critical point to warn of a
potentially hazardous situation.
10.2 Particular attention shall be paid to the following to ensure that by working on electrical
components, the casing is not altered in such a way that the level of protection is affected.
This shall include damage to cables, excessive number of connections, terminals not made
to original specification, damage to seals, incorrect fitting of glands, etc.
Ensure that apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded such that they no longer serve
the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall
be in accordance with the manufacturer s specifications.
NOTE:
The use of silicon sealant may inhibit the effectiveness of some types of leak detection
equipment. Instrinsically safe components do not have to be isolated prior to working on them.
Summary of Contents for HTW-MO2-041IX41B2R32
Page 2: ......
Page 4: ......
Page 38: ......
Page 72: ......
Page 74: ......
Page 98: ......
Page 100: ......
Page 118: ..._ 1 _ f I l _ i 1 _ _ r MODELO 1X4 1010 5 kW 20...
Page 128: ...2...
Page 129: ...3...
Page 130: ...4...
Page 131: ...5...
Page 132: ...6...
Page 133: ...7...
Page 134: ...8...
Page 135: ...9...
Page 136: ...10...
Page 137: ...11...
Page 138: ...12...
Page 139: ...13...
Page 140: ...14...
Page 141: ...15...
Page 142: ...16...
Page 143: ...17...
Page 144: ...18...
Page 145: ...19...
Page 146: ...20...
Page 147: ...21...
Page 148: ...22...
Page 149: ...23...
Page 150: ...24...
Page 151: ...25...
Page 152: ...26...
Page 153: ...27...
Page 154: ...28...
Page 155: ...29...
Page 156: ...30...
Page 157: ...31...
Page 158: ...32...
Page 159: ...33...
Page 160: ...34...
Page 161: ...35...
Page 162: ...36...
Page 163: ...37...
Page 164: ...38...
Page 165: ...39...
Page 166: ...40...
Page 167: ...41...
Page 168: ...42...
Page 170: ......
Page 171: ......