background image

Other Features

BUCKET FULL Light
Glows when the bucket is ready to be emptied,

or when the bucket is removed or not replaced

in the proper position.
Alarm
If the bucket is full or missing for more than three

minutes, an alarm will sound for about 10 seconds

to remind you to empty and replace the bucket.
Auto Shut Off
The Water Level Control Switch shuts off the

dehumidifier when the bucket is full, or when

the bucket is removed or not replaced in the

proper position.
Auto Defrost
When frost builds up on the evaporator coils,

the compressor will cycle off and the fan will

continue to run until the frost disappears.
Power Outage

In the case of a power outage or interruption,

the unit will automatically restart, in the settings

last used, after the power is restored.

NOTE: When the bucket is full or removed, the

controls cannot be set.

ON/OFF Pad

Press to turn the dehumidifier on and off.

FILTER Pad

After 250 hours of operation, the 

Clean the

Filter indicator light will glow to remind you to

clean the filter. Remove the filter and clean it. 
Press to turn off the 

Clean the Filter light. See

the 

Care and Cleaningsection.

Humidity Set Control Pads

The humidity level can be set within a range

of 80% RH  (Relative Humidity) to 35% RH

(Relative Humidity) in 5%  reduce or at

CO for continuous operation.

NOTE: If CO (Continuous) is selected, the

dehumidifier will operate continuously at 

its maximum dehumidification settings if

attached to a hose to drain or until the

bucket is full.

For drier air, press the    

-   pad and set to 

a lower percent value (%).

For damper air, press the    +  pad and set 

to a higher percent value (%).

When you first use the dehumidifier, set 

the humidity control to 45% or 50%. Allow

at least 24 hours for the dehumidifier to

achieve the humidity level. If you still have

damper air than desired, set the humidity

level to a lower setting or select Continuous

for maximum dehumidification.

Display

Shows the set % humidity level while

setting, then shows the actual (+/– 5%

accuracy) room % humidity level.

FAN SPEED  

Controls the fan speed.
Press to select High  or Low fan 

speed.

Set the fan control to High for maximum 

moisture removal. When the humidity 

has been reduced and quiet operation is 

preferred, set the fan control to  Low.

TIMER Pad

3

Controls

This unit has 3-min lag due to the device 

for protecting circuit .In order to prolong 

the compressor's  working life, the compressor 

will not start until the unit has run for 3 minutes.

If unit is turned on and running in timer mode 

for 2hr or 4hr,can turn off the unit. When unit 

stand by and running in timer mode for 2hr or

4

3

2

1

5

6

High and Low fan

indicator lights

Bucket full light indicates

bucket needs to be emptied 

or it is not in the proper place

Continuous operation on

indicator light

Power On

indicator light

Clean the Filter

indicator light

A BOUT THE CONTROLS ON THE DEHUMIDIFIER

(GDN16AJ-K4EBC1A

GDN12AJ-K4EBC1A)

4 hour or 2 hour

  

o

/

n

o

 

y

a

l

e

d

f

indicator lights

Summary of Contents for HTW-DH-16P04

Page 1: ...OWNER S MANUAL PORTABLE P04 Thanks for choossing our product Please read carefully this manual before using the product ENGLISH HTW DH 16P04...

Page 2: ...ce for recycling 4 The appliance shall not be installed in the laundry 5 The appliance shall be installed in accordance with national wiring regulations and must be positioned so that the plug is acce...

Page 3: ...leaning To turn on your unit always use the switch on the control panel Never unplug the dehumidifier while it is working This could damage the electronic circuits Never place anything on top of the u...

Page 4: ...continuously at its maximum dehumidification settings if attached to a hose to drain or until the bucket is full For drier air press the pad and set to a lower percent value For damper air press the...

Page 5: ...ket is removed or not Alarm If the bucket is full or missing for more than three minutes an alarm will sound for about 10 Auto Shut Off The Water Level Control Switch shuts off the dehumidifier when t...

Page 6: ...tended for indoor residential applications only This dehumidifier should not be used for commercial or industrial applications Place the dehumidifier on a smooth level floor strong enough to support t...

Page 7: ...use the hose if using the water tank to collect water When the hose is connected water will be drained out through it onto floor instead of into the tank Do not remove the bucket while the unit is in...

Page 8: ...r the dehumidifier to operate Air Filter The air filter checked and cleaned at least every 250 hours of operation or more often if necessary After 250 hours of operation the Clean the Filter indicator...

Page 9: ...n Doors and windows may not Check all doors windows and other openings be closed tightly are securely closed Clothes dryer may be Install the dehumidifier away from the dryer blowing moisture laden Th...

Page 10: ...cations Take off the power cord and plug and warp them well when you do not use the unit for a long period we suggest you to take following steps to store the unit in good condition Model Rated Voltag...

Page 11: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 93 390 42 20 Fax 93 390 42 05 info htwspain com...

Reviews: