LP- 276 REV. 9.4.14
DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN SUBMERGED IN WATER.
Immediately call a qualified service technician.
The appliance MUST BE replaced if it has been submerged. Attempting to operate an appliance that has been submerged could create
numerous harmful conditions, such as a potential gas leakage causing a fire and/or explosion, or the release of mold, bacteria, or other
harmful particulates into the air. Operating a previously submerged appliance could result in property damage, severe personal injury,
or death.
NOTE:
Appliance damage due to flood or submersion is considered an Act of God, and IS NOT covered under product warranty.
NOTE:
If the boiler is exposed to the following, do not operate until all corrective steps have been made by a qualified serviceman:
•
FIRE
•
DAMAGE
•
WATER
Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee.
B. IMPROPER COMBUSTION
C. GAS
Should overheating occur or gas supply fail to shut off, do not turn off or disconnect electrical supply to the circulator. Instead, shut off
the gas supply at a location external to the appliance.
D. WHEN SERVICING THE BOILER
•
To avoid electric shock, disconnect electrical supply before performing maintenance.
•
To avoid severe burns, allow boiler to cool before servicing.
E. BOILER WATER
•
Do not use petroleum-based cleaning or sealing compounds in a boiler system. These products may damage gaskets and
seals in the system. This can result in substantial property damage.
•
Do not use “homemade cures” or “boiler patent medicines”. Substantial property damage, damage to boiler, and/or serious
personal injury may result.
You must not have a direct connection of the potable water system into the heat exchanger. This could cause flow issues, short cycling,
and an increase of mineral build-up in the unit. This system is designed to have incoming potable water flow through the storage tank
first, then through the heat exchanger.
FAILURE TO PIPE THE UNIT PROPERLY WILL VOID THE WARRANTY.
NOTE:
Damages resulting from incorrect installation or from use of products not approved by HTP, Inc. ARE NOT covered by warranty.
PART 2 – BEFORE YOU START
VWH units must be connected to a storage tank. Failure to connect the VWH to a storage tank WILL VOID the warranty.
Do not obstruct the flow of combustion and ventilating air. Adequate air must be provided for safe operation. Failure to keep the vent
and combustion air intake clear of ice, snow, or other debris could result in property damage, serious personal injury, or death.
Summary of Contents for Mod Con 300 VWH
Page 12: ...12 LP 276 REV 9 4 14 Figure 2 Dimensions and Specifications ...
Page 22: ...22 LP 276 REV 9 4 14 I PIPING DIAGRAMS Figure 6 ...
Page 49: ...49 LP 276 REV 9 4 14 Figure 28 Mod Con Internal Connection Diagram LP 255 ...
Page 63: ...63 LP 276 REV 9 4 14 Figure 31 ...
Page 64: ...64 LP 276 REV 9 4 14 Figure 32 ...
Page 65: ...65 LP 276 REV 9 4 14 Figure 33 NOTE Ceramic Refractory Part 7250P 162 ...
Page 66: ...66 LP 276 REV 9 4 14 Figure 34 ...
Page 67: ...67 LP 276 REV 9 4 14 Figure 35 ...
Page 70: ...70 LP 276 REV 9 4 14 ...
Page 71: ...71 LP 276 REV 9 4 14 ...