background image

  

 

Inverarc 200 TLP 

Owner’s Manual 

180 Joey Drive, Elk Grove Village, IL 60007 ·  Ph.: (847) 357-0700  ·  Fax: (847) 357-0744  ·  Web: www.usaweld.com 

Summary of Contents for Inverarc 200 TLP

Page 1: ...Inverarc 200 TLP Owner s Manual 180 Joey Drive Elk Grove Village IL 60007 Ph 847 357 0700 Fax 847 357 0744 Web www usaweld com...

Page 2: ...than thirty 30 days after the discovery HTP America Inc has reserved the right to make changes in design and or add any improvements to its products at any time without incurring any obligation to in...

Page 3: ...achine are firmly secured in place when the machine is connected to the power supply Insulate yourself from the workbench and from the floor ground use insulating footwear and gloves Keep gloves footw...

Page 4: ...4 Fig 1...

Page 5: ...ltage 100 V No Load Voltage with VRD On Less than 25 V Arc Voltage Stick 20 2 28 V Arc Voltage TIG 10 2 18 V Arc Force Stick Only ARC Welding Mode 0 200 CEL Welding Mode 0 500 Hot Start Stick Only 3 4...

Page 6: ...atter free MIG TIG only though still reduced spatter when stick welding Higher travel speeds Deeper penetration Less heat input which equals less material distortion Ability to weld thinner material t...

Page 7: ...y So while stick rods deposit less material lbs hr than flux cored wire the quality of the deposits is much higher generally speaking What makes stick welding so different than all other welding proce...

Page 8: ...00 years build the same model engine driven welding machines over and over with minimal changes In the last couple of decades however stick welding technology has undergone some major advancements New...

Page 9: ...c Weld Mode Indicator LED 6 Power Indicator LED 7 Over Temp Indicator LED 8 Multifunction Amperage Display 9 Encoder 10 Arc Force Indicator LED 11 Slope Down Function Indicator LED 12 Pulse Function I...

Page 10: ...n Indicator LED Fig 2 12 will blink and the display will read P Fr By turning the encoder Fig 2 9 you can vary the frequency value from 0 4Hz to 5Hz The factory set the base current at 50 of the weldi...

Page 11: ...ndicator LED Fig 2 12 will blink and the display will read P Fr By turning the encoder Fig 2 9 you can vary the frequency value from 0 4Hz to 999Hz The factory set the base current at 25 of the weldin...

Page 12: ...cable assembly must be connected to the negative weld current terminal Fig 2 1 This is commonly referred to as reverse polarity If the specifications show DCEN Direct Current Electrode Negative the e...

Page 13: ...it different In Europe procedures that spec pulse welding exist The pulse welding process is relatively new in the U S so no written procedures that spec pulse welding currently exist For example a 1...

Page 14: ...this you would reduce the max amperage even more For example 110 amps or 120 amps with a 55 amp background current which makes for an average heat input of 110 55 2 82 5 amps With this setting you can...

Reviews: