32
ADVANCED MENU UPFLOW
PRESS “
MENU
” KEY
MENU
SET
AND SCROLL TO “MAIN MENU”. THEN
PRESS “
SET
”
MENU
SET
TILL IT BEEPS. SCROLL TO ADVANCED MENU
= Advanced Menu =
Resin Volume
Refill Rate
Regen. Mode
Backwash Override
Emergency Regen.
Regen. Cycles
History Values
= Main Menu =
Regen. Time Setting
System Capacity
Salt Mode Setting
Brine Pre-Fill Set
Advanced Menu
= Resin Volume =
Depends on model
Press
To Cancel
Press
To Confirm
= Backwash Override =
ON
OFF
Press
To Cancel
Press
To Confirm
= Service Settings =
ON
OFF
Press
To Cancel
Press
To Confirm
= Advanced Menu =
Resin Volume
Refill Rate
Regen. Mode
Backwash Override
Emergency Regen.
Regen. Cycles
History Values
= Regen. Mode =
Days
Calendar
Meter Immediate
Meter Delay
Meter Override
= Advanced Menu =
Resin Volume
Refill Rate
Regen. Mode
Backwash Override
Emergency Regen.
Regen. Cycles
History Values
Setting Complete
Press
To Return
= Refill Rate =
0.2 gpm
Press
To Cancel
Press
To Confirm
Setting Complete
Press
To Return
Setting Complete
Press
To Return
= Advanced Menu =
Resin Volume
Refill Rate
Regen. Mode
Backwash/Rinse
Overide
Emergency Regen.
Regen. Cycles
History Values
= Backwash Duration =
12 Minutes
Press
To Cancel
Press
To Confirm
= Brine Draw Durationn =
123 Minutes
Press
To Cancel
Press
To Confirm
= Rinse Durationn =
15 Minutes
Press
To Cancel
Press
To Confirm
= Refill Duration =
12.5 Minutes
Press
To Cancel
Press
To Confirm
= Backwash Override =
10 Regens
Press
To Cancel
Press
To Confirm
Setting Complete
Press
To Return
= Emergency Regen. =
ON
OFF
Press
To Cancel
Press
To Confirm
= Advanced Menu =
Resin Volume
Refill Rate
Regen. Mode
Backwash Override
Emergency Regen.
Regen. Cycles
History Values
Setting Complete
Press
To Return
Setting Complete
Press
To Return
= Advanced Menu =
Resin Volume
Refill Rate
Regen. Mode
Backwash Override
Emergency Regen.
Regen. Cycles
History Values
= Advanced Menu =
Resin Volume
Refill Rate
Regen. Mode
Backwash Override
Emergency Regen.
Regen. Cycles
Auxillary Output
History Values
= Advanced Menu =
Resin Volume
Refill Rate
Regen. Mode
Backwash Override
Emergency Regen.
Regen. Cycles
Auxillary Output
Service Setting
History Value
s
= Backlit Settings =
Energy Save
Always ON
Press
To Cancel
Press
To Confirm
Setting Complete
Press
To Return
= Advanced Menu =
Resin Volume
Refill Rate
Regen. Mode
Backwash Override
Emergency Regen.
Regen. Cycles
Auxillary Output
Service Setting
Backlit Setting
History Values
Setting Complete
Press
To Return
= Regen. Cycles =
Backwash Duration
Brine Draw Duration
Rinse Duration
Refill Duration
Do Not Touch Values Factory Use Only
RESIN VOLUME
This setting is the amount of ion exchange media used in the system. The value is used to
calculate system capacity and refill time. It is also used to select the pre-engineered valve cycle
settings.
REFILL RATE
This value should match the BLFC flow washer. It is used to calculate the refill time.
REGEN MODE
DAYS
- Every X days the system will regenerate at the regen time.
CALENDAR
- On specific days of the week the system will regenerate at the regen time.
METER IMMEDIATE
- When the volume remaining reaches zero gallons the system will
immediately regenerate.
METER DELAYED
- When the volume remaining goes below the calculated reserve for that
day the system will regenerate at the regen time.
METER OVERID
E - When the volume remaining goes below the calculated reserve for that
day the system will regenerate at the regen time or when X days has passed. Which ever occurs
first.
BACKWASH OVERIDE
This setting can be used to skip the back wash cycle. As an example if the
setting is 10, the system will skip 10 back wash cycles. The setting will only work if the WATER
TYPE is set to CITY for clean water applications.
EMERGENCY REGEN
When set to ON, the system will start a forced regeneration when the remaining capacity
reaches 3%. The regeneration consists of 8 minutes of Brine and 12 minutes of Rinse. The 20
minutes regeneration will restore up to 33% of the system capacity. At the next regeneration
time (2:00 AM), the system will automatically perform a standard regeneration to restore
capacity to 100%.
UF SOFTENER (UP FLOW)
This mode is for the operation of an up flow regenerating softener. The
regeneration sequence is 1.
BRINE MAKE
(REFILL), 2. BRINE, 3. BACKWASH, 4 RINSE, 5. REFILL.
Press “
MENU
” key
MENU
SET
. Press - to advance to Advanced Menu. Press and hold
“SET”
MENU
SET
5 seconds or until you hear a beep. Press
MENU
SET
or
MENU
SET
to choose menu option. Press
“SET”
MENU
SET
to enter. Press
MENU
SET
or
MENU
SET
to change option. Press
“SET”
MENU
SET
to accept.