Field Adjustment of Pressure Switch 

 

 

 
 
The pressure switch can be field set to accommodate local circumstances or preferences. The switch 
comes preset from our factory and should only be changed if you are encountering problems. Before 
changing any settings on an HTI System, run the body maker until the oil is at the normal operating 
temperature (typically between 100-120°F).  
 
 

 1. 

Turn filter system on and allow oil to fill the canister while venting the air  

 

 

 

through the bleed cock on the canister lid. 

 
 

 2. 

As soon as fluid flows from bleed cock, close and secure. 

 
 

 3. 

Slowly close the outlet hose ball valve until the system pressure is at 55-58 PSI as 
shown on the pressure gauge atop the canister.  

 
 

 4. 

Remove  clear  cover  of  pressure  switch. 

Rotate  yellow ring  to  ‘UNLOCK’ position. 

Adjust the set point by rotating the SET ring until the LED illuminates. The RESET 
ring should be set 5 PSI below the level of the SET ring. Place the cover back on the 
switch and open the ball valve to restore full flow to the filter. The filter pump and 
safety relief valve will start to bypass oil internally at 60 PSI so setting the pressure 
sensor  higher  will  defeat  the  purpose  of  informing  the  operator  of  a  pending  filter 
change out. 

 
 
NOTE: Do not attempt to reduce or increase the operating pressure by adjusting the internal  
pressure  relief  valve  on  the  pump.  This  safety  devise  has  been  set  and  locked  into  place  at  the 
factory. Attempting to adjust the pressure setting screw can jam the relief valve and prevent proper 
movement. Improperly removing the acorn nut may also result in air leaking into the system, which 
will require frequent system bleeding until the acorn nut seal is replaced.  
 

 

 

 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for 810-050.2

Page 1: ...ing barrier filtration chromatographic separation and absorption all three of the listed contaminants can be removed from the oil simultaneously and efficiently As the filter traps the contaminants it builds up resistance and the pressure rises At 60 65 PSI the pressure switch activates to alert the operator of the need for filter replacement The proper function of the filter depends on the correc...

Page 2: ...m Do not tamper with the internal valve assembly Simply removing the acorn nut can result in an intake air leak that will require a new gasket to correct Under no circumstance should your unit ever exceed 90 PSI Should this occur shut down the system and contact the HTI Filtration Technical Service Department at 719 490 8800 or email sales htifiltration com for assistance SYSTEM LOCATION Although ...

Page 3: ...10 050 systems operates on both 200 400 VAC 50Hz 230 460 VAC 60 Hz 3 Phase power sources Motors are also available for 575 Volt 60Hz systems upon request The pressure switch operates on 24 VDC power exclusively INITIAL START UP PROCEDURE Upon completion of the electrical and hydraulic connections the filtration system is ready for start up The pressure relief valve is factory set for a maximum pre...

Page 4: ...sure switch Rotate yellow ring to UNLOCK position Adjust the set point by rotating the SET ring until the LED illuminates The RESET ring should be set 5 PSI below the level of the SET ring Place the cover back on the switch and open the ball valve to restore full flow to the filter The filter pump and safety relief valve will start to bypass oil internally at 60 PSI so setting the pressure sensor ...

Page 5: ...n a counterclockwise motion The cup seal on the handle assembly should be smooth and free of rough spots or tears Replacement seals are available Step 6 Slice open the end of the plastic bag holding the new element Remove the new element and set in a clean area Lift used element off of center post Step 7 Slide new filter over the center post Make sure the wire lifting bale is at the top and the bl...

Page 6: ...ce for several years After consulting with the canister manufacturer it has been determined that this can be caused by overtightening the stamped steel 2 piece lid clamps HTI Part 540 012 To prevent distortion of the canister body and lid flanges please follow the following torque specifications for the older 540 012 lid clamps and the newer 540 010 005 V Band clamps 540 012 Alternate tightening f...

Page 7: ......

Page 8: ......

Page 9: ...GET OVER 80 F CHANGE TO LIGHTER GRADE OIL LOW FLOW RATE WITH LOW PRESSURE OIL LEAKING OUT OF SYSTEM CHECK FOR LEAKS IN PLUMBING INSUFFICIENT MOTOR POWER CHECK FOR PROPER PUMP VOLTAGE AND ROTATION OIL BYPASSING THROUGH RELIEF VALVE CONFIRM THAT INTERNAL RELIEF HAS NOT BEEN TAMPERED WITH TAP ON EXTERNAL RELIEF TO RESEAT VALVE LOW FLOW RATE WITH HIGH PRESSURE LOADED FILTER REPLACE FILTER ELEMENT REST...

Page 10: ......

Page 11: ...hall be replaced or repaired at HTI Filtration s option at no charge within 90 days of the receipt of the defective part barring unforeseen delays HTI Filtration shall in no event be responsible for the repairs made by others without the express written permission and consent of HTI Filtration To obtain warranty replacement or repairs defective components or parts should be returned freight prepai...