Doc. No.
DOC- 00036367
REV.
Issued Date
1/12/2007
A06
Revised Date
11/19/2008
Doc. Title
Neon Service Manual
Page
54 of 88
HTC CONFIDENTIAL
SM-TP002-0706
HTC Corporation
3. In “main page”, Check phone status,
Click “Turn on flight mode”
Set the unit to :
* Flight mode
* Make sure all RF function is off (phone,
BT, Wifi..)
Idle current test
4. Measure Idle mode current. Idle current
value must under
32mA
, if over the
criteria, it means M/B failed, please
replace M/B for repair.
Sleep current test
5. After idle current checked, Switch OFF
the unit. Unit is turn off and no display.
Sleep current value must under
1.7mA
, if
over the criteria, it means M/B failed,
please replace M/B for repair.
Conclusion:
If current consumption is passed at both of idle and sleep mode, it means M/B is
GOOD. If there is any item FAILED at idle or sleep mode, it means M/B is failed,
please replace M/B for repair.
Model Jig Type
Button set up matrix
Testing Criteria
A
B
C
D
Idle Current <=
Sleep Current <=
NEON
A
0
8
0
0
32 mA
1.7 mA