1 PRECAUTIONS 

AND 

SAFETY MEASURES 

The instrument has been designed in compliance with the directives relevant to electronic 
measuring instruments. For your safety and in order to prevent damaging the instrument, 
please carefully follow the procedures described in this manual and read all notes 
preceded by symbol 

 with the utmost attention. Before and after carrying out the 

measurements, carefully observe the following instructions: 
 

 

CAUTION 

 

  Do not carry out any measurements in case gas, explosive materials or 

flammables are present, or in humid or dusty environments. 

  Do not carry out any measurement in case you find anomalies in the 

instrument such as deformation, breaks, substance leaks, absence of 
display on the screen, etc. 

  Keep the instrument steady during any measuring operation. 

  Do not carry out any measurements which exceed the working and storage 

temperature ranges specified in § 7.1.1. 

  Only the accessories provided together with the instrument will guarantee 

safety standards. They must be used only if in good conditions and 
replaced with identical models, when necessary. 

  Check that the battery is correctly inserted. 

  Check that the LCD display gives indications consistent with the function 

selected. 

  Do not direct the instrument at very high intensity radiation sources (e.g. the 

sun) in order to prevent damaging the IR sensor. 

  Prevent hits or strong vibrations in order to keep the instrument from 

damage. 

  When bringing the instrument from a cold to a hot environment, leave it on 

long enough for condensation water to evaporate. 

 
In this manual, and on the instrument, the following symbols are used: 
 

 

 

Warning: observe the instructions given in this manual; improper use could 
damage the instrument or its components. 

 

 

Compliant with European Standards 

 

 

1.1 DURING 

USE 

 

 

CAUTION 

 

  Failure to comply with the caution notes and/or instructions may damage 

the instrument or be a source of danger for the operator. 

  Use the instrument only in the temperature ranges indicated in § 7.1.1. 

 

1.2 AFTER 

USE 

When measurement is complete, switch off the instrument. If the instrument is not to be 
used for a long time, remove the battery. 
 

Summary of Contents for THT32

Page 1: ...Copyright HT ITALIA 2016 Version EN 1 01 25 03 2016 ENGLISH User manual...

Page 2: ...e of the object in Blending Fusion function 8 5 2 General menu description 9 5 2 1 Menu EMS 9 5 2 2 Menu UNIT 10 5 2 3 Menu MAXMIN 11 5 2 4 Menu PLT 11 5 2 5 Menu DATE 12 5 2 6 Menu MEMORY 13 5 2 7 Me...

Page 3: ...t will guarantee safety standards They must be used only if in good conditions and replaced with identical models when necessary Check that the battery is correctly inserted Check that the LCD display...

Page 4: ...g Fusion function 3 measuring cursors 6 standard colour palettes Automatic detection of hot cold spots of the image Storage of BMP images on external micro SD card IR sensor resolution 32x31pxl USB po...

Page 5: ...ease contact the Dealer In case the instrument should be returned please follow the instructions given in 8 3 2 INSTRUMENT POWER SUPPLY The instrument is supplied by 1x3 7V rechargeable Li ION battery...

Page 6: ...ENT Fig 1 Description of the instrument s front and backside CAPTION 1 LCD display 2 Function keys Menu Enter 3 Grip 4 In built visual photo camera 5 IR sensor 6 USB port for connecting AC adapter bat...

Page 7: ...connecting AC adapter battery charger 7 Trigger key T 8 Battery compartment cover 9 Hole for tripod insertion Fig 3 Description of the instrument s inputs and outputs CAPTION 1 Inside of the battery...

Page 8: ...Keys The arrow keys allow setting system parameters in the instrument s general menu and defining percentage and distance of the Blending Fusion function see The arrow keys also allow scrolling throu...

Page 9: ...distance of the object in Blending Fusion function The instrument is provided with the Blending Fusion function which allows aligning the infrared and the visual image This function is therefore espec...

Page 10: ...mit infrared radiation according to the kind of material the measured object is made of Table 1 shows the emissivity values for the most common materials Emissivity takes values between 0 mirror or pe...

Page 11: ...enu key to go back to the instrument s main screen 5 2 2 Menu UNIT In this section it is possible to define the temperature measuring unit used by the instrument 1 Select the item UNIT with keys or an...

Page 12: ...e display of MAX and MIN values on the display 3 Press the Menu key to confirm go back to the general menu and to the instrument s main screen 5 2 4 Menu PLT In this section it is possible to select t...

Page 13: ...l selection 2 Use the or keys to select the options Date or Time and press the Enter key to confirm The following screen appears on the instrument s display Fig 11 System date time setting Configurati...

Page 14: ...de 6 Press the Enter key to confirm deletion of the image 7 Press the Menu key to go back to the general menu and to the instrument s main screen 5 2 7 Menu BGT In this section it is possible to set t...

Page 15: ...nd press the Enter key The screen appears on the display Fig 14 Setting of alarm thresholds on measurements 2 Use the or keys to select the options High or Low and press the Enter key to confirm The s...

Page 16: ...confirm go back to the general menu and to the instrument s main screen 5 2 10 Menu DIST In this section it is possible to set the measurement unit of distance associated with the Blending Fusion func...

Page 17: ...reen 5 2 12 Menu INFO In this section it is possible to read the general information of the instrument and the residual memory space of the fitted micro SD card 1 Select the item INFO with keys or and...

Page 18: ...nstrument displays the temperature values associated with the measuring cursors 5 Use the trigger key T to freeze the image The following screen appears on the display Fig 19 Image saving 6 Press the...

Page 19: ...environmental temperature and anyway in a range between 0 C and 50 C 32 F and 122 F When using the instrument for the first time recharge the battery for at least 6 hours 1 Connect the battery charge...

Page 20: ...s on measurements MAX and MIN thresholds Memory micro SD card 4GB 6000 BMP images Max allowed micro SD card 16GB PC interface USB 2 0 Power supply Internal supply rechargeable Li ION battery 3 7V 1400...

Page 21: ...sequence of improper packaging Repairs which may become necessary as a consequence of interventions performed by unauthorized personnel Modifications to the instrument performed without the manufactur...

Reviews: