background image

  

HTFLEX33D 

 

EN – 7

 

7. SERVICE 

7.1. Warranty 

conditions 

This instrument is guaranteed against any defect in material and manufacturing in 
compliance with the general sales terms and conditions. Throughout the period of 
guarantee all defective parts may be replaced and the manufacturer reserves the right to 
repair or replace the product. 
 
If the instrument is to be returned to the after-sales service or to a dealer transportation 
costs are on the customer’s behalf. Shipment shall be however agreed upon. 
 
A report must always be enclosed to a rejected product stating the reasons of its return. To 
ship the instrument use only the original packaging material; any damage that may be due 
to no-original packing shall be charged to the customer. 

 

The manufacturer declines any responsibility for damages caused to persons and/or 
objects.  
 
Warranty is not applied in the following cases: 
 

  Any repair that might be necessary as a consequence of a misuse of the instrument or 

of its use with no compatible devices. 

  Any repair that might be necessary as a consequence of improper packaging. 

  Any repair that might be necessary as a consequence of service actions carried out by 

unauthorized personnel. 

  Any modification of the instrument carried out without the authorization of the 

manufacturer. 

  Use not provided for in the instrument’s specifications or in the instruction manual 

 
The content of this manual cannot be reproduced in any form whatsoever without prior 
authorization of the manufacturer. 
 

All our products are patented and their trade marks registered. The manufacturer 
reserves the right to modify the product specifications and prices if this is aimed at 
technological improvements

 

 
7.2. Service 

If the instrument does not operate properly, before contacting the after-sales service check 
cables as well as test leads and replace them if necessary. Should the instrument still 
operate improperly check that the operation procedure is correct and conforms to the 
instructions given in this manual. If the instrument is to be returned to the after-sales 
service or to a dealer transportation costs are on the customer’s behalf. Shipment shall be 
however agreed upon. A report must always be enclosed to a rejected product stating the 
reasons of its return. To ship the instrument use only the original packaging material; any 
damage that may be due to no-original packing shall be charged to the customer. 

Summary of Contents for HTFLEX33D

Page 1: ... Copyright HT ITALIA 2013 Release EN 2 00 24 06 2013 ENGLISH User manual ...

Page 2: ...CRIPTION 3 2 1 Introduction 3 2 2 Transducer s functions 4 3 INSTALLATION 5 4 MAINTENANCE 5 5 END OF LIFE 5 6 TECHNICAL SPECIFICATIONS 6 6 1 Reference standards 6 6 2 Technical features 6 6 3 Mechanical features 6 6 4 Environment conditions 6 7 SERVICE 7 7 1 Warranty conditions 7 7 2 Service 7 ...

Page 3: ...e the current flowing is greater than the maximum measurable current Overrange CAUTION Hazardous potentials may exist in the vicinity of the desired current measurements Use locally approved safety procedures when working near hazardous potentials It is recommended not to install the clamp around a live bus that is at a hazardous potential If installation is not possible when the bus is inactive o...

Page 4: ...ring instrument take the clamp off the cable wait 1 minute before connecting the clamp to the measuring instrument then clamp the cable again Do not use the HTFLEX33D if is or seems damaged 2 INSTRUMENT DESCRIPTION 2 1 Introduction HTFLEX33D is an innovative current transducer based on the Rogowsky s principle that combines easy use with measurement accuracy The HTFLEX33D current probe is similar ...

Page 5: ...s from other current measuring methods The measuring transducers are constructed from non ferrous materials minimizing any circuit loading due to magnetic influence Fig 2 Measurement transducer The frequency response of the current probes is rather wide compared to conventional CTs This allows the user to monitor a much wider range of line harmonic components than conventional CTs allow The HTFLEX...

Page 6: ...ing a HTFLEX33D current probes Each transducer has been Hi Pot tested to several thousand volts with no voltage breakdown This particular characteristic allows high current measurement with a wide frequency bandwidth of conductors at less than 1000VAC potential to earth CAUTION Hazardous potentials may exist in the vicinity of the desired current measurements Use locally approved safety procedures...

Page 7: ...Range 3dB 10Hz 20kHz Phase Error 45 65 Hz 1 Position Sensitivity 2 rdg Temperature Coefficient 0 05 rdg per C Working voltage 1000V DC ACrms 6 3 Mechanical features Output connection 2 m cable with 3 way Hypertac connector Length of flexible clamp 610mm 24in Maximum conductor diameter 174mm 7in Weight 215g 8 ounces Material TPE Polypropylene UL94 VO rated Mechanical protection IP65 6 4 Environment...

Page 8: ...be necessary as a consequence of service actions carried out by unauthorized personnel Any modification of the instrument carried out without the authorization of the manufacturer Use not provided for in the instrument s specifications or in the instruction manual The content of this manual cannot be reproduced in any form whatsoever without prior authorization of the manufacturer All our products...