5
resting on by pressing down firmly at each corner and observing if the isolation
base rocks up and down. If any rocking motion occurs, adjust the G7 foot at the
rocking corner by turning it counter-clockwise (as viewed from below base
frame)
1
/
8
of a rotation at a time until it no longer rocks under pressure. Always
maintain at least three full rotations of thread engagement on each G7 foot.
Optimal performance will be achieved when at least three G7 footers are threaded
fully into the frame and only one foot is adjusted to prevent rocking. The G7 feet
are not designed to level the base frame. Leveling of the R3X Isolation Base is
done by adjusting the HRS frame or other supporting structure.
SF2 height: 1.300”
SF3 height: 1.300”
LF2 height: 1.475”
LF3 height: 1.475”
G7 Height 1.350”
Bottom SF2 / LF2
Bottom SF3 / LF3
Bottom G7
Note: The listed heights above are from bottom to top of outer metal housing only
(not to the top of isolators, shims, or threads)