![HRS MXR Manual Download Page 6](http://html1.mh-extra.com/html/hrs/mxr/mxr_manual_2177330006.webp)
Panel Brace Installation
- You are now ready to attach the primary brace system
to the panel. There are two braces that hold the two end panels together to form
the primary MXR Frame Structure. There are two rectangular spacers attached
to each brace system when it is shipped that need to be loosened to complete
assembly. Simply take the T-wrench or Allen wrench supplied with the MXR and
loosen (counter clockwise) each of the eight nuts on the brace assembly (see
Photo 7). You do not want to have lots of play in the assembly, you just want to
break the torque on each nut so that the brace can be properly located.
Photo 7
The HRS logo is machined into the center of each brace. Locate the HRS logo on
the brace and orient it so that when the stand is upright on its feet, the logo will
be in correct orientation. There are two steps at each end of the brace sub
assembly that fit precisely over the attachment block on the panel. Slowly lower
the brace assembly onto the block until the steps in the brace contact the block
(see Photo 8 and Photo 9). Attach at least one of the 1/4-20 x 3/4" screws to the
brace assembly (see Photo 10) prior to removing your hand from the assembly to
insure it stays in place. It is very important that the 3/4" long screws are used at
this location to obtain proper thread engagement.
Photo 8 Photo 9