background image

 

     

HIROSE ELECTRIC CO.,LTD.

 

ETAD-T0401-01

 

4

 /

 

FORM HC0011-9-2 

 

 
 
(3) Inserting crimped terminals into housings 
 

Insert a crimped GT36 female terminal along the terminal insertion hole into the housing to the 
end. After insertion, check if the terminal engagement is inserted into the housing engagement.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
* Coaxial cables and available cavities 
 

GT36A-4S-HU(*)

×

GT36A-4S-CV

         

 

Cavities 

Coaxial cables 

1.5D 

1.5D 

1.5D foaming (ETC)/2.5D 

1.5D 

   
 

GT36A2-4S-HU(*)

×

GT36A2-4S-CV

         

 

Cavities 

Coaxial cables 

1.5D foaming (ETC)/2.5D 

1.5D 

1.5D foaming (ETC)/2.5D 

1.5D 

                                                                                                            Viewed from engagement side 
 

GT36A3-4S-HU(*)

×

GT36A3-4S-CV

       

 

Cavities 

Coaxial cables 

1.5D 

1.5D 

1.5D 

1.5D foaming (ETC)/2.5D 

   

 

   

 

 
 
 

1      Table Deleted 

Terminal engagement 

Terminal 
insertion hole 

Housing engagement 

Oct.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Summary of Contents for GT36A

Page 1: ...ADA 20190311 名 称 TITLE INSTRUCTION MANUAL FOR GT36A CONNECTOR APPROVED KI HIROKAWA 20171128 CHECKED KI HIROKAWA 20171128 DESIGNED KJ OBINATA 20171128 WRITTEN KJ OBINATA 20171128 TECHNICAL SPECIFICATION ETAD T0401 01 1 1 7 FORM HC0011 9 1 HIROSE ELECTRIC CO LTD Oct 1 2022 Copyright 2022 HIROSE ELECTRIC CO LTD All Rights Reserved ...

Page 2: ...111 0 00 For 1 5D foaming ETC GT36A Female housing Hirose part name Hirose part number Remarks GT36A 4S HU A CL786 0030 5 00 1 5D three ETC 2 5D one GT36A 4S HU B CL786 0031 8 00 1 5D three ETC 2 5D one GT36A 4S HU C CL786 0032 0 00 1 5D three ETC 2 5D one GT36A2 4S HU D CL786 0024 2 00 1 5D two ETC 2 5D two GT36A 4S HU D CL786 0043 0 00 1 5D three ETC 2 5D one GT36A3 4S HU B CL786 0117 0 00 1 5D ...

Page 3: ...length See below for the dimension L after wiring and the cable cutting length Cable cutting length L1 9 6 L2 17 5 2 Crimping terminals Refer to the terminal instruction manual for the terminal crimping procedures and crimping quality standards ETAD T0392 01 ETAD T0400 01 Oct 1 2022 Copyright 2022 HIROSE ELECTRIC CO LTD All Rights Reserved ...

Page 4: ...ables and available cavities GT36A 4S HU GT36A 4S CV Cavities Coaxial cables A 1 5D B 1 5D C 1 5D foaming ETC 2 5D D 1 5D GT36A2 4S HU GT36A2 4S CV Cavities Coaxial cables A 1 5D foaming ETC 2 5D B 1 5D C 1 5D foaming ETC 2 5D D 1 5D Viewed from engagement side GT36A3 4S HU GT36A3 4S CV Cavities Coaxial cables A 1 5D B 1 5D C 1 5D D 1 5D foaming ETC 2 5D 1 Table Deleted Terminal engagement Termina...

Page 5: ...the GT36A cover into the GT36A housing until it is engaged with the housing engagement and a click sound is heard Make sure that it is engaged with the engagement Housing engagement Engagement Cover Oct 1 2022 Copyright 2022 HIROSE ELECTRIC CO LTD All Rights Reserved ...

Page 6: ...e connector Insert the connector until it is locked and a click sound is heard After completion of work pull the connector in the disconnection direction and make sure that it does not come out The above figure shows the unfinished engaged condition The above figure shows the engaged condition Engagement direction Notch Cable pullout side Oct 1 2022 Copyright 2022 HIROSE ELECTRIC CO LTD All Rights...

Page 7: ...rm terminals when touching them 7 Storage Conditions Storage place Temperature humidity conditions Storage period Indoor storage 15 30 60 RH or less Six months in our packing condition Store the products in a place that meets the following conditions if they cannot be stored in an air conditioned warehouse as shown above Do not store the products in a place with much humidity or dust exposure to d...

Reviews: