TITLE
:
TJA Series Guideline
ETAD-E3232-00
Rev No. 0
HIROSE ELECTRIC CO.,LTD.
OBJECT
PRODUCT
:
TJA Series
PAGE:
19
OF
25
3.4 Cable Clamping Method
To accommodate a variety of cables, a large space for clamping the cables is needed.
Therefore, the cable may not be secured depending on the cable diameter,
sheath material and composition, the number of pins, etc. Adjust the thickness
with a shrink tube or copper tape so that the cable can be secured .
※Recommended cable tensile strength: 98 N
The metal clamp of CV1 can be reinforced with a cable tie as indicated below.
When a load is applied to the cable, optionally fix the cable to the metal clamp with a cable
tie. The cable tie is not provided, so please prepare it.
Depending on the position of the coupling part of the cable tie, it may be difficult to grip
the connector body. In that case, fix it so that the coupling part of the cable tie contacts the
ridged part of the metal clamp.
In addition, please secure the cable to the wall or floor in an environment where vibration is
applied. If the cable is fixed within 25 cm from the cable clamp and there is no slack,
the connector cannot be inserted or removed, so please fix it around 30 cm from the clamp.
Please fix the cable around
30 cm from the cable clamp
Image of cable tie fastening
Image of cable tie size
Cable tie
Cable tie fastening part : Position
Difficult to Grip Connector Body
Cable tie fastening part : Ridged Part Position
Coupling part of the cable
tie on the side of the case
and a finger cannot enter.
Coupling Part of the Cable Tie
Metal Clamp
Ridged part
Aug.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved.