background image

VDPLT2/VDPLT3/VDPLT4  

VELLEMAN 

3

4.

 

Description 

 

 

1.

 

LED tube 

2.

 

mounting clips (w/ screws) 

3.

 

male input connector 

4.

 

female output connector 

 

 

5.

 

Connection 

 

1.

 

Signal input: Low voltage signal input to be connected with the signal output from the previous tube or with 
the controller. 

2.

 

Signal output: Low voltage signal output to be connected with the signal of the next tube. If there is no 
further tube to be connected, you must seal this connector against humidity if the tubes are used outdoor. 

 

 

 

 

The tube(s) should be installed out of reach of people and outside areas where people can walk or touch the 

tube(s). 

 

Install the included clips in a proper and safe way. Make sure the surface is strong enough and is able to 

carry the structure. 

 

Click the tubes into the clips. 

 

Interconnect the tubes and the VDPLTC2 controller (not incl.) through the input/output connectors. Make 

sure the connectors are properly connected. 

 

6. Cleaning and Maintenance 

 

1.  All screws should be tightened and free of corrosion. 
2.  The housing, the mounting supports and the installation location (e.g. ceiling, suspension, trussing) should not be 

deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not change the location 
of the connections… 

3.  Mechanically moving parts must not show any signs of wear and tear. 
4.  The electric power supply cables must not show any damage. Have a qualified technician maintain the device. 

5.  Disconnect the device from the mains prior to maintenance activities. 
6.  Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents. 

7.  There are no user-serviceable parts. 
8.  Contact your dealer for spare parts if necessary. 

 

Summary of Contents for VDPLT2

Page 1: ...A GEBRUIK NOTICE MANUAL BEDIENU DPLT LED TUBE ARANTE UMINEUX UMINOSO ARENTE ANUAL KERSHA D EMPLO L DEL US UNGSAN T2 E E LEDBUI X LED T O CON LE LED R NDLEIDIN OI SUARIO LEITUNG VD S TRANSPA EDs TRAN H...

Page 2: ...t h ass I It is the tion does not exc otect it agains ns to clean it ce as sensitiv odifications t and unautho onal use on s ing current of permanent o e force when protected aga ce of 0 5m be x the d...

Page 3: ...lick the tubes into the clips Interconnect the tubes and the VDPLTC2 controller not incl through the input output connectors Make sure the connectors are properly connected 6 Cleaning and Maintenance...

Page 4: ...DPLT3 31 x 500mm VDPLT4 31 x 1 000mm Total Weight VDPLT2 90g VDPLT3 160g VDPLT4 280g Max Ambient Temperature 45 C Max Housing Temperature 80 C Use this device with original accessories only Velleman n...

Page 5: ...nbe sioneel gebru 30 VAC 50 H or continue w mijd brute kra me temperatu m tussen de li hikte veilighe el kennen voo schadiging h ng wanneer u ruiker geen w atie raak gee tel niet aang 5 T4 TRA duct in...

Page 6: ...VDPLTC2 controller niet meegelev via de in en uitgangsaansluitingen Zorg ervoor dat de connectoren goed in hun aansluiting zitten 6 Reiniging en onderhoud 1 Alle gebruikte schroeven moeten goed zijn a...

Page 7: ...31 x 500 mm VDPLT4 31 x 1 000 mm Gewicht VDPLT2 90 g VDPLT3 160 g VDPLT4 280 g Max omgevingstemperatuur 45 C Max temperatuur van de behuizing 80 C Gebruik dit toestel enkel met originele accessoires V...

Page 8: ...our le n ource lumineu s modification PLT4 hors de sage profess A de max 23 our une op r l appareil av rot g contre pecter une dis e s curit ad nt de l appar d g ts sont allage origine nterdite pour o...

Page 9: ...onnecter les tubes et le contr leur VDPLTC2 not incl l aide des connexions d entr e de sortie Veiller ce que les fiches soit d ment ins rer dans les connexions 6 Nettoyage et entretien 1 Serrer les cr...

Page 10: ...VDPLT4 31 x 1 000 mm Poids VDPLT2 90 g VDPLT3 160 g VDPLT4 280 g Temp rature ambiante max 45 C Temp rature max du bo tier 80 C N employer cet appareil qu avec des accessoires d origine SA Velleman ne...

Page 11: ...ayo y prot jalo co stribuidor ree o va a usarlo tar el cable d luz Esto pue ones no autor LT4 lejos de uso profesio fuente de cor nterrumpido siva fuerza d de el aparato pete una dista ridad adecua de...

Page 12: ...lips incluidos de manera correcta y segura Aseg rese de que la superficie portante pueda sostener la estructura Introduzca el los tubo s en los clips hasta que oiga un clic Interconecte los tubos y el...

Page 13: ...00 mm VDPLT4 31 x 1 000 mm Peso VDPLT2 90 g VDPLT3 160 g VDPLT4 280 g Temperatura ambiente m x 45 C Temperatura m x de la caja 80 C Utilice este aparato s lo con los accesorios originales Velleman NV...

Page 14: ...nleitung ung nicht geq das Kabel er utzung und v nie an der N htquelle da be m chtige n m Ger t fern onellen Einsa enr umen un anenten Betr eiden Sie roh tionsortes da hnische Dat d irgendeiner eignet...

Page 15: ...Sie die mitgelieferten Montageclips auf eine sichere und korrekte Weise Beachten Sie dass die Oberfl che das Ger t tragen kann Klicken Sie die LED R hre in die Montageclips Verbinden Sie die LED R hre...

Page 16: ...VDPLT2 31 x 200 mm VDPLT3 31 x 500 mm VDPLT4 31 x 1 000 mm Gewicht VDPLT2 90 g VDPLT3 160 g VDPLT4 280 g Max Umgebungstemperatur 45 C Max Temperatur Geh use 80 C Verwenden Sie dieses Ger t nur mit ori...

Reviews: