VDPL300LS
V. 02 – 22/08/2014
8
©Velleman nv
7.
Cleaning and maintenance
Disconnect the device from mains before starting maintenance operation.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
•
All screws used for installing the devices or parts of the device have to be tightly connected and must
not be corroded.
•
There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
•
The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Use a soft lint-free and moistened cloth. Never use alcohol or
solvents.
There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
7.1
Replacing the fuse
If the fuse of the device blows, only replace it with a fuse of same type and rating (see "Technical
Specifications").
1.
Disconnect the device from the mains before starting maintenance operation.
2.
Open the fuse holder on the rear panel with a fitting screwdriver.
3.
Remove the old fuse and insert a new one.
4.
Screw the fuse holder back into the housing.
Should you need any spare parts, use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
8.
Technical Specifications
power supply
230Vac/50Hz
power consumption
20W
fuse
T1A, 250V
DMX connection
3-pin XLR in- and output
number of LEDs
160pcs (40pcs of each colour)
beam angle
46°
dimensions
240 x 325 x 345mm
weight
3.5kg
Use this device with original accessories only. Velleman nv cannot be held responsible in the event
of damage or injury resulted from (incorrect) use of this device.
For more info concerning this product and the latest version of this manual, please visit our website
www.hqpower.eu.