background image

 

VDP6504BL 

V. 04 – 31/07/2014 

©Velleman nv 

 

Connect the device to the mains with the power plug. All devices must be powered directly off a grounded 
switched circuit and cannot be run off a rheostat or dimmer circuit, even if the rheostat or dimmer channel 
is used solely for 0 % to 100 % switching. 

 

The installation has to be approved by an expert before the device is taken into service. 

6.

 

Use 

Plug the power socket into the power supply (230 VAC, 50 Hz). This blinder is DMX-controlled via one channel. 

DMX-512 Connection 

 

When applicable, connect an XLR cable to the female XLR output of a controller (not incl.) and the other 
side to the male XLR input of the device. Multiple devices can be linked through serial linking. The linking 
cable should be a dual core, screened cable with XLR input and output connectors. 

 

Maximum recommended serial data link distance is 500 meters (1640 ft). Maximum recommended number 
of devices on a serial data link is 32 devices. 

 

DMX chain with terminator: 
A DMX terminator is recommended for installations where the DMX cable has 
to run a long distance or used in an electrically noisy environment (e.g. 
discos). The terminator prevents corruption of the digital control signal by 
electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω 
resistor between pins 2 and 3, which is then plugged into the XLR output 
socket of the last device in the chain. 

 

 

DMX Start Address Selection 

 

All DMX-controlled devices need a digital start address so that the correct device responds to the signals. 
This digital start address is the channel number from which the device starts to “listen” to the DMX 
controller. The same starting address can be used for a whole group of devices or an individual address can 
be set for every device. 

 

When all devices have the same address, all the units will “listen” to the control signal on one particular 
channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you 
set individual addresses, each device will “listen” to a separate channel number. Changing the settings of 
one channel will only affect the device in question. 

 

In case of the 1-channel mode, you will have to set the start address of the first unit to 1 (CH1), the second 
to 2 (CH2), the third to 3 (CH3), and so on. The highest start address is 512. 

DMX Address Setting 

You can select the address by setting the DIP switches. DIP switch 10 always has to be ON. 
The DMX start address of the fixture is defined by DIP switches 1-10. The encoding is binary: DIP switch 1 has 
value 1, DIP switch 2 has value 2, DIP switch 3 has value 4, DIP switch 4 has value 8, etc. 

 

DIP switch 

10 

Value 

16 

32 

64 

128 

256 

 

For example: For start address 95, the settings are (for switches 1-10): 1111101000 (1 + 2 + 4 + 8 + 16 + 0 
+ 64 = 95). 

7.

 

Cleaning and Maintenance 

 

All screws should be tightened and free of corrosion. 

 

The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension, 
trussing) should not be deformed, modified or tampered with; e.g. do not drill extra holes in mounting 
supports, do not change the location of the connections… 

 

Mechanically moving parts must not show any signs of wear and tear. 

 

The electric power supply cables must not show any damage. Have a qualified technician maintain the 
device. 

 

Disconnect the device from the mains prior to maintenance activities. Let the device cool down. 

 

Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents. 

 

Do not immerse the device in any liquid. 

 

There are no user-serviceable parts, apart from the lamp (see “Installation”). 

 

Contact your dealer for spare parts if necessary. 

Summary of Contents for VDP6504BL

Page 1: ...GE BLINDER DMX GESTUURDE STAGE BLINDER STAGE BLINDER CONTR LE DMX STAGE BLINDER CONTROLADO POR DMX DMX GESTEUERTER STAGE BLINDER USER MANUAL 2 GEBRUIKERSHANDLEIDING 5 MODE D EMPLOI 9 MANUAL DEL USUARI...

Page 2: ...Do not stare directly at the light source as this may cause epileptic seizure in sensitive people temporarily loss of sight flash blindness permanent irreversible eye damage There are no user service...

Page 3: ...justable to choose the requested angle for 4 x PAR36 DWE 650 W 120 V lamps 5 Installation Lamps Only fit or replace a lamp when the device is unplugged from the mains Let a lamp cool down before repla...

Page 4: ...address can be set for every device When all devices have the same address all the units will listen to the control signal on one particular channel In other words changing the settings of one channe...

Page 5: ...one huishoudelijke afval het moet bij een gespecialiseerd bedrijf terechtkomen voor recyclage U moet dit toestel naar uw verdeler of naar een lokaal recyclagepunt brengen Respecteer de plaatselijke mi...

Page 6: ...toestel kennen voor u het gaat gebruiken Ongeschoolde personen mogen dit toestel niet gebruiken Meestal is beschadiging het gevolg van onprofessioneel gebruik Om veiligheidsredenen mag u geen wijzigin...

Page 7: ...oestel regelmatig nakijken Monteer het toestel niet zelf indien u er geen ervaring mee heeft Een slechte montage kan leiden tot verwondingen Regel de gewenste invalshoek door middel van de montagebeug...

Page 8: ...en mogen geen sporen van roest vertonen De behuizing de lenzen de montagebeugels en de montageplaats bv het plafond of het gebinte mogen niet vervormd zijn of aangepast worden geen extra gaten in mont...

Page 9: ...l hors de la port e des enfants et des personnes non autoris es Attention l appareil chauffe pendant l usage Ne pas regarder directement dans la source lumineuse afin d viter les risques de crise d pi...

Page 10: ...ux est une r glette lumineuse qui est con ue pour subir une puissance maximale pendant un bref d lai N utilisez pas cette r glette lumineuse puissance maximale au del des dix secondes Transporter l ap...

Page 11: ...ison DMX est recommander si le c ble DMX doit couvrir une grande distance ou s il est utilis dans un environnement avec beaucoup de bruit lectrique p ex une discoth que La r sistance de terminaison pr...

Page 12: ...ouvant r sulter de l utilisation de cet appareil Pour plus d information concernant cet article et la derni re version de cette notice visiter notre site web www hqpower eu Toutes les informations pr...

Page 13: ...por ejemplo por grietas o rasgu os profundos Fije el aparato con un cable de seguridad adecuado p ej VDLSC7N o VDLSC8N La temperatura ambiente m x es 45 C No utilice el aparato a temperaturas m s alta...

Page 14: ...a etc Un t cnico especializado debe revisar el aparato antes de la puesta en marcha Despu s debe revisarlo una vez al a o Instale el aparato fuera del alcance de personas no autorizadas y en un lugar...

Page 15: ...a posici n ON La direcci n inicial DMX del aparato se determina por los conmutadores DIP n 1 10 El c digo es binario el valor del DIP n 1 es 1 DIP n 2 2 DIP n 3 4 DIP n 4 8 etc Conmutador DIP 1 2 3 4...

Page 16: ...zu lebensgef hrlichen elektrischen Schl gen f hren Trennen Sie das Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz Fassen Sie dazu den Netzstecker an der Grifffl che an und ziehen Sie nie a...

Page 17: ...den bernimmt der Hersteller keine Haftung Lassen Sie dieses Ger t von einem Fachmann installieren und warten Das Ger t bei Temperaturschwankungen nicht sofort einschalten Sch tzen Sie das Ger t vor Be...

Page 18: ...fert und die andere Seite mit dem XLR Eingang des Ger tes Sie k nnen verschiedene Ger te in Serie schalten Verwenden Sie ein zweipoliges abgeschirmtes Kabel mit XLR Ein und Ausgangsanschl ssen Die max...

Page 19: ...dwelche L sungsmittel Tauchen Sie das Ger t nicht ein Es gibt keine wartbaren Teile au er der Lampe siehe Installation Bestellen Sie eventuelle Ersatzunterteile bei Ihrem Fachh ndler 8 Technische Date...

Page 20: ...niet oplaadbare ingebouwd of vervangbaar lampen rubberen onderdelen aandrijfriemen onbeperkte lijst defecten ten gevolge van brand waterschade bliksem ongevallen natuurrampen enz defecten veroorzaakt...

Page 21: ...echos La lista previamente mencionada puede ser adaptada seg n el tipo de art culo v ase el manual del usuario del art culo en cuesti n Velleman Service und Qualit tsgarantie Seit der Gr ndung in 1972...

Reviews: