LPTP406 GB
3
5. Connections
a) Mains Input
The colour coding for the wires inside the cable (3 x 1.5mm
2
) is as follows :
Brown = positive (L), blue = neutral (N), green/yellow = earth (E).
Make sure the earth connectors are properly connected before you operate the device.
b) Mains Output
The signal output goes through 4 CEE output sockets. A load can be applied to each of these
output sockets. The maximum load allowed per channel is 920W (resistive load) or 460W
(inductive load). Do not surpass the maximum total current of 16A !