VDP250SC6M
VELLEMAN
5
f) Detailed DMX values per channel
Description
From To Function
CHANNEL 1
Pan
0 255 8 bit
CHANNEL 2
Tilt
0 255 8 bit
0
18 white
18 35 dark blue
36 53 pink
54 71 light green
72 89 orange
90 107 light blue
108 126 yellow
127
red
128 191 forward rainbow effect
CHANNEL 3
Colour Wheel
192 255 Backward Rainbow effect
0
15 open
16 31
32 47
48 63
64 79
80 95
96 111
112 127
128 191 forward gobo cycle (slow -> fast)
CHANNEL 4
Gobo Wheel
192 255 backward gobo cycle (slow –> fast)
0
15 no rotation
16 135 forward gobo rotation (fast-> slow)
CHANNEL 5
Gobo Rotation
136 255 backward gobo rotation (slow -> fast)
0
5 shutter closed
6 128 dimmer control
129 131 reset (after 3-5 seconds)
132 139 shutter open
140 199 strobe (slow -> fast)
200 249 random strobe (slow -> fast)
CHANNEL 6
Strobe
250 255 shutter open
By means of the provided DMX cable it is possible to chain multiple units together for synchronous operation.
6. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, the lenses, the mounting supports and the installation location should not be deformed or modified
or tampered with.
3. Mechanically moving parts must not show any signs of wear and tear.
4. The electric power supply cables must not be damaged. Have a qualified technician check the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts, apart from the lamp.
8. Contact your dealer for spare parts if necessary.