background image

Understanding the controls

Adjusting the duration time:

The length of time that remains switched on after activation can be 
adjusted from 10±5 seconds to 4±1 minutes. Rotating the TIME knob 
anticlockwise from (+) to(-) reduces the duration time. Note: Once the light 
has been triggered by the PIR sensor any subsequent detection will start 
the timed period again from the beginning.

Adjusting the LUX control level:

The LUX control module has a built-in sensing device (photocell) that 
detects daylight and darkness. Rotate the LUX knob anticlockwise from 
light ( ) to dark ( ). The ( ) position will allow the floodlight to work day 
and night, and the ( ) position works only at night. You can set the unit to 
operate at the desired level by adjusting the LUX knob.

Setting the controls:

1.  Turn the LUX control knob to light ( ) position, turn the wall switch on 

and wait 30 seconds for the control circuit to stabilise. Ensure the TIME 
control knob is set at minimum (-).The floodlights on the sensor light will 
now switch on and will remain on for about 10sec.

2.  Direct the sensor toward the desired scanning area by adjusting the 

elbow joint and swivel joint on the sensor arm. Important: loosen  
all lock nuts and screws on sensor arm and lamp holders before 
making any adjustments.

3.  Have someone move across the centre of the area to be scanned and 

slowly adjust the angle of the sensor arm until the unit senses the 
moving person, causing the floodlights to switch on. (Refer Fig.1 B)

4.  Adjust time control to required setting.
5.  To set the light level at which the floodlights will automatically switch 

“On”, turn the LUX control knob from daylight to night. If the floodlights 
are required to switch on earlier, e.g. dusk, wait for the desired light level, 
then slowly turn the LUX control knob towards daylight while someone 
walks across the centre of the area to be detected. When the floodlights 
switch on, release the LUX knob. You may need to make further 
adjustments to achieve your ideal light level setting.

Important: when adjusting lamp holders, ensure that the PAR38 LED 
Globes are not touching or in close proximity to sensor head, heat from 
the PAR38 LED Globes may distort the unit. To avoid dust build-up and 
ensure proper functioning of the sensor light, wipe the sensor lens lightly 
with a damp cloth every 3 months. Never modify the unit, there are no 
user serviceable parts inside.

Specifications:

Voltage supply: 230-240Va.c. 50Hz
Power consumption: 29W
Total lumen output: 2200lm (1100lm per globe)
Maximum load: 2 x 150W PAR38
Weatherproof: IP44
Operating temperature: -10ºC to 50ºC
Detection circuitry: PIR (Passive Infrared)
Detection range: 12M (max), 120º scan.
Time adjustment: 10±5 seconds to 4±1 minutes.
Adjustable LUX
Replacement LED globe: LPAR38013K (non-dimmable)

EASY SETUP GUIDE

With sensor fully installed by electrician and  

power on:

1.  Rotate “TIME” dial anti-clockwise to minimum(-)
2.  Rotate “SENS” dial clockwise to m)
3.  Rotate “LUX” dial clockwise to daylight (SUN)
4.  Wait for sensor to turn off (30 seconds to 1 minute)
5.  Move around (walk past or wave hands and arms) and the sensor 

should turn on the lamps if you are close enough

6.  You can adjust the sensor head direction and lamp directions until 

you achieve the desired setup

7.  Once tested and satisfied the time dial can be turned anti-

clockwise to the desired time duration

8.  For “LUX” setup, adjust the “LUX” dial anti-clockwise to minimum 

(moon), and wait until light conditions outside are at the level you 
wish the sensor to operate. (For instance dusk)

9.  Adjust the “LUX” dial clockwise until the lamps turn on.

Dial settings show  

TEST MODE