background image

8.

Secure front of rail to the front RETMA column
using the provided flat securing screw/guide pin in
the bottom screw position of the rail.

9.

Slide the enclosure into position on the rails (1).
Secure the chassis into the rack by tightening the
captive CTO screw behind the latch on the front left
and right bezel ears of the chassis (2).

CAUTION: 

The front CTO screw must be

attached at all times when racked.

10.

Attach the rear hold down brackets by sliding the
tab with the arrow pointed forward (1) into the
corresponding slot on each side of the rear of the
chassis. Use the black headed thumb screw to
secure the chassis tightly to the rail (2).

11.

Install the base server unit into the rack and secure
it using the thumbscrews on the front bezel of the
unit.

Installing the server node and storage
enclosure in the rack - 5250 and 5650

CAUTION: 

Use extreme caution when installing

and pulling units from the rack. Units can slip and
fall, damaging the HPE StoreOnce System or
causing personal injury. Hewlett Packard
Enterprise is not responsible for damage or injury
caused by mishandling the HPE StoreOnce
System.

Procedure

1.

Install the rails, as illustrated on the installation
instructions that ship with the rail kit.

NOTE: 

To leave room for future storage expansion,

install the base storage enclosure under the server
node. The 5250 has a maximum of one enclosure
above the server node and one enclosure under the
it. The 5650 has a maximum of two enclosures above
the server node and two enclosures under it.

2.

Insert the eight locking nuts for the storage enclosure
into the rack; two on each column.

To locate the position for the locking nuts, count up
4U from the bottom of the rails (1). Place a nut on
either side of the +4U position on each rack column
(2).

Page 4     

Summary of Contents for StoreOnce 5200

Page 1: ...d 5650 Systems Installation Guide in the following cases The system includes optional storage products or capacity upgrade kits The system arrived without PCIe cards pre installed or requires addition...

Page 2: ...cumentation for detailed instructions including safety information about installing units within the rack Ensure that you have sufficient personnel or lifting equipment to install the storage enclosur...

Page 3: ...nting the rails 3 Position left and right rack rails at the desired U position in the rack adjusting the rails to fit the rack as needed Front and Rear bottom edge of rails must align with the bottom...

Page 4: ...de and storage enclosure in the rack 5250 and 5650 CAUTION Use extreme caution when installing and pulling units from the rack Units can slip and fall damaging the HPE StoreOnce System or causing pers...

Page 5: ...uts for the server node into the rack one on each front column 7 Install the server node into the rack and secure it using the thumbscrews on the front bezel of the unit Attaching the security bezel P...

Page 6: ...IA P2 Connecting the storage enclosure power cables Procedure StoreOnce 5200 Connect two power cables to each enclosure Connect each power cable to a different PDU StoreOnce 5250 and 5650 Connect four...

Page 7: ..._________________ iLO gateway _____________________________ Configuring the basic network Procedure 1 Log in using the default user name and password Default user name console Default password changem...

Page 8: ...Procedure 1 Navigate to http www hpe com info storeonce docs 2 In Models Subcategories select your product 3 To filter the entries select the types of documents and your language Page 8...

Reviews: