Removal and replacement procedures 40
Heatsink
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
To remove the component:
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Remove the access panel (on page
4.
Place the server on its side.
5.
Remove the heatsink:
a.
Disconnect the processor fan cable.
b.
Loosen one pair of diagonally opposite screws halfway, and then loosen the other pair of screws.
c.
Completely loosen all screws in the same sequence.
d.
Remove the heatsink from the processor backplate.
To replace the component:
1.
Clean the old thermal grease from the processor with the alcohol swab. Allow the alcohol to
evaporate before continuing.
Summary of Contents for ProLiant ML10 Gen9
Page 12: ...Customer self repair 12...
Page 13: ...Customer self repair 13...
Page 14: ...Customer self repair 14...
Page 17: ...Illustrated parts catalog 17...
Page 21: ...Illustrated parts catalog 21...
Page 64: ...Component identification 64 The following image shows the drive numbering...
Page 68: ...Cabling 68 Front USB cabling Fan cabling System fan...
Page 70: ...Cabling 70 Ambient temperature sensor cabling...