18.
Connect each power cord to the power source.
20.
If removed,
The installation is complete.
M.2 SSD enablement option
The server supports the installation of one M.2 SSD enablement board. Each enablement board can
support two M.2 SSDs. The M.2 SSD enablement board is supported in the PCIe3 expansion slots 1–4.
Use the embedded HPE Smart Array S100i SR Gen10 Controller to manage the M.2 SATA SSDs. The
S100i SR Gen10 SW RAID support requires that the server boot mode be set to UEFI.
Installing an M.2 SSD enablement option
The DL180 Gen10 M.2 cable kit is required to meet the system thermal requirement. Do not use the M.2
cable that ships with the M.2 SSD enablement option.
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
• M.2 SSD enablement option
• M.2 SSD
• DL180 Gen10 M.2 cable kit (PN 875135-B21)
• T-10 Torx screwdriver
• Phillips No. 1 screwdriver – required only if the M.2 SSD is not preinstalled on the enablement board.
Procedure
1.
.
2.
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Disconnect all peripheral cables from the server.
5.
Do one of the following:
•
Extend the server from the rack
•
Remove the server from the rack
.
6.
.
7.
8.
Remove the expansion slot blank
.
9.
If the SSD is not preinstalled on the M.2 SSD enablement board, do the following:
82
Hardware options installation
Summary of Contents for ProLiant DL180
Page 30: ...24 bay SFF hot plug drive model Fan bay numbering 30 Component identification...
Page 58: ...SFF 4 Install the drive LFF SFF 58 Hardware options installation...
Page 97: ...Secondary riser cage Slot 4 Slot 5 or 6 Hardware options installation 97...
Page 128: ...Box 2 to type a controller Box 2 to type p controller 128 Cabling...
Page 129: ...Box 3 to system board Box 3 to type a controller Cabling 129...
Page 130: ...Box 3 to type p controller 8 bay SFF power cable default 130 Cabling...
Page 135: ...Mini SAS cable to SAS expander Cabling 135...
Page 137: ...M 2 SSD enablement board installed in secondary riser Cabling 137...
Page 142: ...Cable routing Serial port Cable routing iLO Service Port SFF LFF 142 Cabling...
Page 144: ...Secondary riser cage Slot 4 Slot 5 or 6 144 Cabling...