• Extend the server from the rack.
• Remove the server from the rack.
6.
Place the server on a flat, level work surface.
8.
Remove any components or cables that may prevent access to the TPM connector.
9.
Proceed to
Installing the TPM board and cover
Installing the TPM board and cover
Procedure
1.
Observe the following alerts:
CAUTION:
If the TPM is removed from the original server and powered up on a different server,
data stored in the TPM including keys will be erased.
CAUTION:
The TPM is keyed to install only in the orientation shown. Any attempt to install the
TPM in a different orientation might result in damage to the TPM or system board.
2.
Align the TPM board with the key on the connector, and then install the TPM board. To seat the board,
press the TPM board firmly into the connector. To locate the TPM connector on the system board, see
the server label on the access panel.
3.
Install the TPM cover:
a.
Line up the tabs on the cover with the openings on either side of the TPM connector.
b.
To snap the cover into place, firmly press straight down on the middle of the cover.
Hardware options installation
119
Summary of Contents for ProLiant DL180
Page 30: ...24 bay SFF hot plug drive model Fan bay numbering 30 Component identification...
Page 58: ...SFF 4 Install the drive LFF SFF 58 Hardware options installation...
Page 97: ...Secondary riser cage Slot 4 Slot 5 or 6 Hardware options installation 97...
Page 128: ...Box 2 to type a controller Box 2 to type p controller 128 Cabling...
Page 129: ...Box 3 to system board Box 3 to type a controller Cabling 129...
Page 130: ...Box 3 to type p controller 8 bay SFF power cable default 130 Cabling...
Page 135: ...Mini SAS cable to SAS expander Cabling 135...
Page 137: ...M 2 SSD enablement board installed in secondary riser Cabling 137...
Page 142: ...Cable routing Serial port Cable routing iLO Service Port SFF LFF 142 Cabling...
Page 144: ...Secondary riser cage Slot 4 Slot 5 or 6 144 Cabling...