default VLAN. VLAN 2 and VLAN 3 are used internally by the embedded switch within the system, and
cannot be configured as tagged VLANs on the cartridges.
Accessing the System Utilities menu
About this task
To complete these steps, you need the HPE USB-to-serial cable (HPE part number 871947-B21).
Table 1: Settings for connecting USB cable to serial port
Specifications
Value
Baud rate
115200
Data bits
8
Parity
None
Stop bit
1 (8 N1)
Procedure
1.
Power down the cartridge.
2.
Connect the USB-to-serial cable to the system. The USB end is connected to a system USB port.
3.
Attach the serial end of the cable to a serial port using a null modem cable. The other serial port may
be another USB-to-serial adapter on a different machine.
4.
Power on the cartridge. The serial console output screen displays.
5.
Press the
ESC
+
9
keys. The System Utilities menu displays.
Accessing the System Utilities menu
29