background image

6. 

Install the 12V DC power cables: 

a. 

Insert the cable through the wide opening on either end of 

the power shelf, and then connect it to the appropriate 

connector.   

 

b. 

Slide the cables toward the center, allowing them to 

straighten and hang from the rear of the power shelf. 

 

7. 

Install the cable guard. 

   

 

NOTE:

  Cables are removed for clarity. 

   

 

8. 

Install the power supply vent cover to protect the power supply 

vents. 

 

 

Connecting the chassis to a power 

shelf 

   

 

IMPORTANT:

  To complete this procedure, be sure to 

locate the power management cable (part number 

745919-001). 

   

To install the component: 

1. 

Connect the power cables from the chassis power cage to the 

power shelf. 

2. 

Connect the power management cable to the chassis 

management module with the cable's plastic tab facing up. 

   

 

CAUTION: 

  To prevent damage to the power 

management cable, release the cable by pressing the 

latches when disconnecting, instead of pulling directly. 

   

   

 

IMPORTANT:

  When connecting the power 

management cable to the chassis management module 

and the power shelf, be sure to install the cable with the 

plastic tab on the top of the connector. Failure to install 

the cable properly can result in performance and 

reporting issues. 

   

 

3. 

Connect the power management cable to the power shelf with 

the cable's plastic tab facing up. 

   

 

CAUTION: 

  To prevent damage to the power 

management cable, release the cable by pressing the 

latches when disconnecting, instead of pulling directly. 

   

   

Summary of Contents for Apollo a6000

Page 1: ...ower cage left 9 Power management cable 10 HPE Apollo a6000 Chassis Rail kit 11 Service tray The quantity depends on the configuration ordered Not shown Copyright 2014 2016 Hewlett Packard Enterprise Development LP The information contained herein is subject to change without notice The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty state...

Page 2: ...ve the packing materials from the pallet 3 Place the chassis in the location selected in step 1 Chassis component identification Before installing front or rear components into the chassis review chassis slot numbering for each component Server tray bay numbering Rear panel components Item Description 1 I O modules 10 2 Fan assemblies 5 3 Power cage Right 4 Management module 5 Power cage Left Fan ...

Page 3: ...ge operate server trays only when the open side of the server tray is enclosed by either another server tray a divider or the chassis wall Install all server trays into each chassis Installing a server tray blank CAUTION To prevent improper cooling and thermal damage operate server trays only when the open side of the server tray is enclosed by either another server tray a divider or the chassis w...

Page 4: ...s are populated with a component or a blank Installing an I O module Install the component as indicated Installing a system fan Installing a power cage CAUTION To prevent damage to the component power down the chassis and disconnect all power cords before removing or installing the component CAUTION Do not overtighten the screws Hewlett Packard Enterprise recommends using a torque of only 2 4 in l...

Page 5: ...own the chassis and disconnect all power cords before removing or installing the component To install the component 1 Install the power shelf rack rails into the rack For more information see the HPE Power Shelf Rack Rail Kit for HPE and Third Party Racks Installation Instructions 2 Install the power shelf 3 Secure the power shelf to the rack 4 Install the power supplies into the power shelf if ne...

Page 6: ...the chassis power cage to the power shelf 2 Connect the power management cable to the chassis management module with the cable s plastic tab facing up CAUTION To prevent damage to the power management cable release the cable by pressing the latches when disconnecting instead of pulling directly IMPORTANT When connecting the power management cable to the chassis management module and the power shel...

Page 7: ...nfigurations Configuration examples can be calculated using the HPE Power Advisor Tool http www hpe com info poweradvisor online This tool is designed for facilities planning purposes only Values obtained from the tool are based on worst case loads Whenever possible Hewlett Packard Enterprise recommends using actual measurements in configuration planning Measurements must be made with the intended...

Page 8: ...e optional HPE APM module IMPORTANT If you have an HPE APM module connected to an Apollo a6000 Chassis do not connect the iLO port of the HPE APM module and the iLO port of the enclosure to the network at the same time Having both ports connected at the same time results in a loopback condition 1 Connect the HPE APM module to the network shown in green 2 Connect the HPE APM module to the chassis s...

Page 9: ...to assist with interpreting and resolving error messages on ProLiant servers and server blades The documents are on the Hewlett Packard Enterprise website http www hpe com support proliantgen9 docs The installation is complete For more information For more detailed setup and configuration information see the Advanced Power Manager User Guide For safety information and regulatory notices see the re...

Reviews: