7
8/8/2014 800
12)
For FPS - Key valve assembly sequence is the same for either natural gas or LP.
a.
Nipple > Elbow > Valve > Elbow > Gas Supply
13)
Connect fuel supply line to Key Valve.
14)
Perform leak test as described in this manual.
15)
Install unit in enclosure.
a)
I
To reduce whistling ensure any flex line does not have sharp bends.
8)
Fire Pit Operation
WARNING:
Before use, be sure to test all gas connections for leaks. Do not use fire pit if there is any evidence of leaking gas. If
leaking gas suspected, turn off the main gas supply and repair immediately.
WARNING:
Do not use enclosure as a seating area. Wind and gusty conditions will affect the flame in an unpredictable manner. If
conditions exist that are not safe for patrons turn the fire pit off.
WARNING:
Do not use fire pit if any part has been submerged under water. Immediately call a qualified service technician to
inspect the fire pit.
WARNING:
For electronic ignition models power to fire pit must be turned off via wall switch or breaker when not in operation.
WARNING:
Never use any material that is non-porous and holds moisture such as gravel, pebbles, river rock, etc. This material,
when heated will cause the trapped moisture to boil and fracture unexpectedly. This material is not sufficiently porous to allow
heated steam to readily escape which can break and cause personal injury or damage.
WARNING:
Solid fuels shall not be burned in the fire pit. Leaves, sticks, wood, paper, clothing, food material, should be kept
away from the fire pit. Fire Pit is not for cooking. Make sure that there is no vegetation or other objects over the top or sides of the
fire pit that could interfere with safe operation. See clearances in section 2 Selecting the Location.
WARNING:
If lava rock is wet, allow fire pit to burn for 45 minutes prior to coming within 15 feet of the fire pit.
WARNING:
When fire pit is not in operation turn off gas valve.
WARRANTY REQUIREMENT:
When not in use the fire pit must be covered at all times.
IMPORTANT
:
Initial
Start-up:
It may be necessary to purge air in gas lines after system installation
.
START UP
1.
STOP! Read the safety information on “What to do if you smell gas” (Pg. 1).
2.
Ensure fire pit is clear of people, debris, that all covers are removed, and the feature is safe to start.
3.
Place long handled lighter or match while burning on top of the fire pit.
4.
Slowly turn “ON” gas valve.
5.
After burner lights remove lighter or match.
6.
Adjust flame to desired height.
7.
If burner does not light turn valve off and allow gas to clear then repeat steps 3~7.
8.
Never alter the design of the fire pit.
9.
Ensure fire pit, children and patrons are supervised by a responsible adult that is familiar with emergency shut-down.
10.
Flammable materials should not be placed on or near the fire pit.
11.
Inspect the fuel supply connection ( including all quick disconnect hoses) before use.
a.
Replace hose if there is evidence of abrasion or wear.
12.
Only Use “ US Department of Transportation” Approved LP cylinders.
13.
LP gas cylinder supply system must be properly vented.
14.
Turn off LP cylinder when not in use.
Summary of Contents for Match Lit
Page 9: ...9 8 8 2014 800 ...