background image

8/8/2014                                                        800 

Index: 

1)

 

General Information 

2)

 

Selecting the Location 

3)

 

Construction of Enclosure 

4)

 

Installation of Fire Pit 

5)

 

Media 

Product Specific Information  

6)

 

Parts List 

7)

 

Assembly 

8)

 

Fire Pit Operation 

9)

 

Maintenance 

10)

 

Troubleshooting 

11)

 

Warranty 

 

1)

 

General Information 

 

Instructions are also available at HPCfire.com 

 

Please carefully follow the instructions in this manual to prevent personal injury or property loss.  Instructions are 
updated as needed.  It is the installer’s responsibility to periodically review instruction for applicable updates. 

 

The steps listed as: 

 

WARNINGS:

  Contains information critical to the safe installation and operation of the fire-pit. 

WARRANTY REQUIREMENT: 

Must be strictly followed to qualify for product warranty

.  

Warranty will be void if not followed. 

IMPORTANT: 

Are notes and insights to help ensure product satisfaction and serviceability. 

-------------------------------------------------------------------------------------------------------------------------------------------------              

WARNING:

 

 

It is the installer’s responsibility to ensure a safe installation and to educate the end user as to proper 

operation.  Leave this manual with the end user. 

WARNING:

 

 Never

 

alter product or configuration in any way. 

WARNING:

 

FOR REMOTE CONTROL USE: 

This family of product is not for use with any type of remote or 

start-up timer control.

  

WARNING:

 

We suggest that our products be installed by professionals that are locally licensed by the authority having  

jurisdiction in gas piping.  We suggest that our products be serviced annually by a professional certified in the US by the  
National Fireplace Institute (NFI) as NFI Gas Specialists or in Canada by WETT (Wood Energy Technical Training).   
Installer must follow all instructions carefully to ensure proper performance and safety.  Hearth Products Controls  
Company is not responsible for your actions.   

WARNING

:

  Product is not intended to be a starter for wood or any other combustibles.  

WARNING:

  

It is the responsibility of the installer to follow:    

o

 

The 

National Fuel Gas Code

ANSI Z223.1/NFPA 54

 or 

International Fuel Gas Code. 

o

 

The 

National Electrical Code, ANSI/NFPA 70

o

 

Local Codes 

WARNING:

  

Only use gas/fuel type specified for this fire pit see label on the fire pit control Box.  Verify correct 

gas/fuel type and pressure.  Never use an alternative fuel to include bio-fuel, ethanol, lighter fluid or any other fuel. 
 

             Gas pressure and type should be checked prior to use and installation. 

             

 

                

 Natural Gas Fire Pit:  

Supply Pressure: Minimum: 3.5” W.C.; Maximum: 7.0” W.C.   
 

 

                

 LP Gas: 

Supply Pressure: Minimum: 8.0” W.C.; Maximum: 11.0” W.C.   
 
 
 
 

Summary of Contents for Match Lit

Page 1: ...vice or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANG...

Page 2: ...ONTROL USE This family of product is not for use with any type of remote or start up timer control WARNING We suggest that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping We suggest that our products be serviced annually by a professional certified in the US by the National Fireplace Institute NFI as NFI Gas Specialists or in ...

Page 3: ...t or on adjacent wall to allow for emergency shutdown and maintenance Verify correct 110VAC or 24VAC Supply WARNING All fire pits must have a gas shutoff on the outside of the exterior of the fire pit to allow for emergency shut off and maintenance WARNING Always use proper materials and construction for gas supply power and enclosure WARNING The enclosure must incorporate 1 vent on at least two o...

Page 4: ...e Perform leak test on main gas supply Repair leaks as necessary Shut Off Gas Supply and Power to fire pit Connect fire pit to main gas supply If using flex line avoid sharp bends with flex line to prevent whistling Turn on gas supply and perform leak test on all inlet connections Repair as needed For electronic ignition models hook up proper 110VAC or 24VAC electrical power following all local co...

Page 5: ...cation 1 Install your fire pit per instructions 2 Apply lava rock ONLY deep enough to cover ring and pan less than 2 above fire ring For Electronic Ignition 3 Blow Out Box Do not cover vents with lava rock leave open Do not allow any rock to block flame opening 4 Blowout Box Do not cover blowout box vents or opening with lava rock or glass Incorrect media installation will cause the pilot flame to...

Page 6: ...rner will be used indoors it is the installer s responsibility to follow all regulations local codes and achieve independent certifications WARNING Confirm Gas In is towards control valve or shutoff valve Installing backwards will result in severe gas leak and risk of explosion If your air mixer has an adjustment nut adjust to desire flame condition WARNING A pan must be used on LP systems and con...

Page 7: ...aper clothing food material should be kept away from the fire pit Fire Pit is not for cooking Make sure that there is no vegetation or other objects over the top or sides of the fire pit that could interfere with safe operation See clearances in section 2 Selecting the Location WARNING If lava rock is wet allow fire pit to burn for 45 minutes prior to coming within 15 feet of the fire pit WARNING ...

Page 8: ...ential causes and countermeasures to the symptoms indicated in bold If still unable to resolve issue please contact your retailer or certified technician Will Not Light 1 Air in gas line If new install may take several attempts to purge air 2 Debris in gas line Confirm gas line is clear insulation dirt plastic excessive pipe sealer etc 3 Gas Pressure Improper Confirm proper gas pressure found Sect...

Page 9: ...9 8 8 2014 800 ...

Page 10: ...10 8 8 2014 800 ...

Reviews: