EL-MF877-00
Template Revision A
Page 7
678155-001 (HP Z620 Workstation Disassembly Instructions)
2.
Lift and pull handle to remove the top plate of the power supply chassis. The unit will fall open into
two parts, as shown in the following figure.
3.
Ensure that all capacitors are safely discharged. Use a diagonal cutter to remove the desired
components from the PCA. (Note that some components may need to be unsoldered if a diagonal
cutter does not fit between the component and the PCA.)
4.
Dispose of all removed components according to regulatory requirements.