SNMP configuration parameters
If you are using SNMP, record the configuration parameters in the following table.
Table 4-11 Onboard Administrator SNMP configuration parameters
Description
Possible value
Value
Parameter
The SNMP location of the
enclosure
0 to 20 characters, including
alphanumeric, dash,
underscore, and space
System location
The name of the system contact
0 to 20 characters, including
alphanumeric, dash,
underscore, and space
System contact
The read community name.
Default: public.
0 to 20 characters, including
alphanumeric, dash, and
underscore
Read community
The write community name.
Default: blank.
0 to 20 characters, including
alphanumeric, dash, and
underscore
Write community
The management station IP
address
###.###.###.###, where ###
ranges from 0 to 255
SNMP alert destination IP
address
A text string that acts as a
password that authenticates
messages sent between HP SIM
and HP Onboard Administrator
0 to 20 characters, including
alphanumeric, dash, and
underscore
SNMP alert destination
community string
Power management configuration parameters
Record the configuration parameters in the following table.
Table 4-12 Onboard Administrator power management configuration parameters
Description
Possible value
Value
Parameter
The chosen redundant operation
mode for the power subsystem
AC Redundant, Power Supply
Redundant, or Not Redundant
Enclosure Power mode
Yes is the default value because
the dynamic power mode saves
power in most situations. When
enabled, Dynamic Power Server
mode runs the required power
supplies at a higher rate of use.
Unused power supplies remain
in standby mode.
Yes or No
Dynamic Power Savings mode
—
Yes or No
Enable Enclosure AC Input
Watts Limit
If a data center has a cooling
capacity limitation for the
maximum number of VA (watts)
that can be cooled per
enclosure, set a VA limit.
Cooling capacity information
can be obtained from your
facilities manager. Setting the
Input VA limit to less than the
maximum VA supplied by the
selected power supply mode
limits the number of devices that
can be powered up and keeps
the enclosure within the cooling
capacity of the data center.
2,700 VA to 16,400 VA
Enclosure Input Watts Limit
The management station IP
address
###.###.###.###, where ###
ranges from 0 to 255
SNMP alert destination IP
address
A text string that acts as a
password that authenticates
messages sent between HP SIM
and HP Onboard Administrator
0 to 20 characters, including
alphanumeric, dash, and
underscore
SNMP alert destination
community string
32
Onboard Administrator installation configuration parameters