TRANSMIT CONFIGURATION
STRINGS
Disable this setting when using a modem that is
not compatible with the supported modem
(MT5634ZBA).
IMPORTANT:
Do not mix HP and VT100 terminal types.
The remote serial port parameters are as follows:
MODEM PROTOCOL
Bell or CCITT. CCITT is a European standard;
RTS/CTS signaling is used as well as the Ring
signal. Bell is a U.S. or simple mode.
BAUD RATES
Input and output data rates are the same — 300,
1200, 2400, 4800, 9600, 38400, 115200
bps.
FLOW CONTROL
Hardware uses RTS/CTS; software uses
Xon/Xoff.
TRANSMIT CONFIGURATION
STRINGS
Disable this setting when using a modem that is
not compatible with the supported modem
(MT5634ZBA).
MODEM PRESENCE
When the modem is not always connected, set
this parameter to
not always connected
.
CG
Generates an RSA key pair or Self-Signed Certificate. This command generates a new
RSA key pair and self-signed certificate.
CL
Console Log. View the history of the console output. This command displays up to 60
KB of logged console data (about 60 pages of display in text mode) sent from the
system to the console path.
CM
Command Mode. Enter command mode. This command switches the console terminal
from the MP Main Menu to mirrored command interface mode. If the current mux
authority is administrator and the new login is as an operator, the command mux is
denied (remains in MP Main Menu mode). If a command is in progress, a message is
displayed warning the new user of system status.
CO
Console. Leave command mode and enter console mode. This command switches the
console terminal from the MP Main Menu to mirrored (redirected) console mode. All
mirrored data is displayed. Press
CTRL+B
to return to the MP command interface.
For VT100 and HPTERM, verify that the MP setting in the
CO
command is correct and
that all mirrored consoles are of the same terminal type for proper operation.
CSP
Connects to a remote MP over the LAN. This command enables the local or remote
port user to connect over the MP LAN to another MP on the network. The user who
launches the command is given a private connection to the other MP over the LAN. To
return to the original MP, press
CTRL+]
to disconnect the CSP session.
DATE
Displays the current date, as generated in the MP real-time clock.
DC
Default Configuration. Resets all MP parameters to the default configuration. This
command sets all MP parameters back to their default values. You can reset all or a
subset of the following parameters:
•
IP configurations
•
Modem configuration
•
Paging configuration
•
Command interface configuration
MP Commands
9