QuickSpecs
HPE Virtual Connect FlexFabric-20/40 F8 Module
Technical Specifications
Page 19
Relative Humidity
(noncondensing)
***
Operating
10% to 90%
Shipping
10% to 90%
*
CAUTION:
To avoid damage to the equipment, if more than two HPE Virtual Connect FlexFabric-20/40
F8 Modules are installed in a c7000 enclosure, the ambient operating temperature cannot exceed 30C
(86F).
**
CAUTION:
All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m
(1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit
is 3,048m (10,000 ft) or 70 Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3
KPa/4.4 psia.
***
CAUTION:
Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F).
Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.
Power Specification
12V @ 13.75A (165 W)
Product
Specifications
Software
Security Features
•
HTTPS (HTTP exchanged over an SSL-encrypted session) is required for
access to the Virtual Connect Manager. Access to the Virtual Connect
Manager is via the system Onboard Administrator.
•
Each user account can be configured for a combination of four access
privileges to control and/or view elements in the Virtual Connect Manager.
•
User verification by account name and password (Case Sensitive).
•
Role based customization to assign various privileges to Server Admin,
Network Admin and Storage Admin.
•
LDAP Authentication services provide role based security via an LDAP SSL
Directory Server connection.
•
authentication, authorization and accounting
•
RADIUS authentication and authorization
•
Administrator controlled password length and strength requirements.
•
Private VLANs for secure connectivity between servers within a domain.
•
Compliant with United States Department of Defense
Policy on Use of
Department of Defense (DoD) Information Systems Standard Consent
Banner and User Agreement.
•
Configurable filtering of multicast traffic
•
GUI and CLI session timeout
Trunking, Failover
and Other
Networking
Features
•
Shared Uplink Sets using Link Aggregation Control Protocol (LACP) allows
the creation of Ethernet channeling with upstream switches that conform to
IEEE 802.3ad. Ports can alternatively be configured for failover only.
•
External ports within a Port Set can be on the same VC Ethernet module or on
multiple VC modules within the VC domain.
•
In the event of an uplink failure to a data center switch, the next highest
performance uplink connection or aggregation will become active.
•
Fast MAC Cache failover enables rapid recovery of network connections when
a standby module becomes active.
•
Smart Link network senses a failed upstream switch connection and allows
teamed NICs to properly failover.