troubleshooting your hp visualization center sv6
troubleshooting tree
Chapter 1
27
✓
Call HP Support and report an sv6 X server problem.
NOTE
Only one graphics card per Workstation is supported for sv6
configurations.
12. sv6 Specific Software Problems
• Graphics software patches must be the same across all master and
slave systems.
❏
If you get version mismatch errors at x server start-up, update
graphics patches on all systems (see sv6 Installation/ Users
Guide).
• Red check marks at X server startup screen.
❏
Check
/etc/X11/X0screens
file for typos or invalid
configurations.
❏
Troubleshoot the first system with a red check mark.
❏
Other check mark colors:
White: Slave system has been contacted
Yellow: Slave has been configured for use in SLS/d or sv6
Blue: Slave X server has been started
Green: Slave X server has been reached and communication has
been established
Red: Error
sv6 startup error and warning messages
Master Error Messages:
•
Duplicate Slave entries detected in X*screens file
.
Edit
/etc/X11/X0screens
and look for two slave nodes that have
the same hostname.
•
I
nvalid number of Slaves for current mode of operation.
Run /
opt/graphics/OpenGL/sv/bin/setpipes
to set a screen
layout that is appropriate for your configuration.
•
Bad default visual detected for one or more Slaves.