troubleshooting your hp visualization center sv6
troubleshooting tree
Chapter 1
21
✓
NIS domain name (optional)
✓
NIS server name or address (optional)
•
If you don’t see a green LED on the Workstation’s 10/100 LAN cable,
see the “Network Attachment Problems” section.
• If you can’t get to a prompt, see the “Network Attachment Problems”
section, and look up HP-UX 11.0 documentation at
http://www.docs.hp.com
.
• If CDE doesn’t come up at boot time, go to:
—
init:2
—
init:4
❏
If that doesn’t work, at the init 2 main menu prompt, type:
X:0
This will start up an X server. You should see a gray pattern
(called root weave) on the monitor. Press
Ctrl+C
to exit.
Did you see the root weave pattern?
If Yes - Try another Window Manager i.e. run the
/var/opt/ignite/sps/sv6files/startX0script
to see if mwm works. If so, you may have a CDE problem.
If No - Go to the “X server” or “Windows Manager Problems”
section of this document.
• If you see just a black screen.
❏
Make sure your output device (monitor) is plugged into the
Compositor and that all DVI cables connect the Compositor to the
graphics cards on the Workstations.
❏
Make sure all Workstations, monitors, and other components in
the rack are powered ON.
• For more assistance refer to HP-UX 11.0 ACE or J6000
documentation at
www.hp.com/workstations/support
and
www.docs.hp.com.
• Report boot problems to HP Support as HP-UX 11.0 ACE 64 bit on
J6000.
5. Network Attachment Problems
• If your systems can talk to each other, but not to the sites’s network: